.  Safety information

In the event of danger!

 

Interrupt the flow of fuel (gas) and cut off the power supply

If you smell gas!

 

Do not smoke
No open fire 
Avoid sparks
Do not switch on lights or other electric appliances
Open windows and doors
Close the gas shut off valve
Contact the heater company/licensed installer
Observe the safety guidelines on the gas counter
Observe the safety guidelines of the heater company

If you smell exhaust gas!

Switch the system off
Open all windows and doors
Notify a specialist heating firm

Fresh air supply 

Fresh and exhaust air openings must not be closed. Closure of fresh air 
supply openings may lead to incomplete combustion and in turn to the pro-
duction of poisonous gases.
This does not apply if your system is operated independent of boiler room 
air.

 

Commissioning of a newly installed system may only be carried out by a quali-
fied installer.The installation control must be completed prior to commissioning 
-see chapter 5.

.1  Safety precautions

Checking the water level - see page 15

Always keep the room in which the boiler is ocated clean and turn off the burner 
before starting the cleaning to avoid any faults due to dusty combustion air. 

Corrosion prevention:

Don’t use sprays, solvents, purifying agents, colours, glues etc. close to the 
boiler. These substances may cause corroision in the boiler and the flue gas 
pipe.

.  Intended use

Intended use:
The TopGas

®

 boiler may only be operated with the fuels indicated in the In-

formation/ Installation instructions.
The heat produced must be carried away by the heating water. All boiler ope-
nings must be closed during operation.

i

. Safety information

Summary of Contents for TopGas classic 12

Page 1: ...7 EN Subject to modifications Hoval United Kingdom Hoval LTD Northgate Newark Nottinghamshire NG24 1JN Phone 44 1636 67 27 11 Fax 44 1636 67 35 32 Hoval Export Hovalwerk AG Austrasse 70 9490 Vaduz Pri...

Page 2: ...Functional principle of the heating system 7 8 5 System start up 8 5 1 Checks prior to start up 8 5 2 Switching on the system 8 6 Heating system control 9 6 1 Operating elements of the boiler control...

Page 3: ...elephone numbers Heating installer Plumbing installer Electrical installer Chimney inspector Fuel supplier 1 2 Key to symbols used i Instruction Prompts you to carry out an action Result Shows the exp...

Page 4: ...equipment Yes No Condensate pump Yes No Outside temperature sensor Yes No Room temperature sensor Yes No Room air dependent Yes No Room air independent Yes No Number of heating circuits 1 2 3 4 Heatin...

Page 5: ...This does not apply if your system is operated independent of boiler room air Commissioning of a newly installed system may only be carried out by a quali fied installer The installation control must...

Page 6: ...ce The reliable and safe functioning of a gas boiler as well as the achievement of an optimal effectiveness and clean combustion are only possible and guaranteed if the system is maintained and cleane...

Page 7: ...ner Radiators underfloor heating Delivers the heat from the heating water to the room Heating pump Pumps the heating water from the boiler to the radiators and back to the boiler where it is heated up...

Page 8: ...ning the TopGas the stench trap siphon in the conden sate drain pipe must be filled with water 5 1 Checks prior to start up Check the water level in the heating system The heating system must be fille...

Page 9: ...sure which does not cause a reaction in any of the operating modes is displayed for information only Off no heating requirement The appliance is ready for operation and will be turned on immediately w...

Page 10: ...art attempts are permitted before the unit registers a malfunction Operating Mode Heat During the heating operation the target temperature is shown in the two digit display If the service button is pr...

Page 11: ...rmation key Show the operating data on the display Return to the basic display without saving the values 7 Heating curve set up Set the heating characteristics 8 Operating mode selection key Select th...

Page 12: ...display Return to the basic display without saving the values 7 Heating curve set up Set the heating characteristics Key Designation Function 9 Display The basic display shows the day of the week dat...

Page 13: ...off frost protection activated 9 Manual mode emission measurement For heating technician only 10 Display The basic display shows the day of the week date and time of the day as well as the current bo...

Page 14: ...l for the heater control Check water level and water pressure Top off the heat system and bleed off air 15 Are the radiator valve open Open the valves The heater circ pump is not running Open the latc...

Page 15: ...ons Press the On Off button to turn the appliance off LED is dark the water pressure is displayed The heater flow and return valves must be open The boiler fill and drain faucet is accessible on the u...

Page 16: ...ng wasted You therefore save fuel if you keep windows and doors closed in winter close chimney dampers when the fire is out only operate kitchen and ba throom fans when it is necessary to remove moist...

Page 17: ...ng heating boilers for oil and wood firing burners solar energy production systems collectors and heat pumps for making use of geo thermal heat or heat generated by wind and water Heat distribution sy...

Page 18: ...7243 550 15 www hoval at Hoval Italia S r l Via per Azzano San Paolo 26 28 I 24050 Grassobbio BG Telefono 39 035 52 50 69 Telefax 39 035 52 58 58 www hoval it Germany Switzerland Austria Italy France...

Reviews: