background image

4 Operation

 

User reference guide

4

Bela08+16I3 + Belar08+16I3

Hoval BelariaSRM and Hoval Belaria compact SRM

4P330441-1 – 2012.11

4 211 876 / 00 – 11/12

Part

Description

Domestic hot water
control

How to control domestic hot water:

▪ Reheat mode

▪ Scheduled mode

▪ Sch reheat mode

Advanced usage

Information about:

▪ Quiet mode

▪ Holiday mode

▪ Reading out information

▪ Date,  time,  units  of  measurement,

contrast and backlight

▪ User profile and home pages

▪ Locking  and  unlocking  buttons  and

functions

Preset values and
schedules

▪ How to use preset values

▪ How to select and program schedules.

▪ Overview of predefined schedules

Menu structure

Overview of menu structure

Installer settings table

Overview of installer settings

4.2

The user interface at a glance

4.2.1

Buttons

a

e

f

b

d

c

a

 HOME PAGES

▪ Switches  between  home  pages  (when  you  are  on  a  home

page).

▪ Goes  to  the  default  home  page  (when  you  are  in  the  menu

structure).

b

 MALFUNCTION INFORMATION

If a malfunction occurs,   is displayed on the home pages. You
can press 

 to display more information about the malfunction.

c

 ON/OFF

Turns  ON  or  OFF  one  of  the  controls  (room  temperature,
leaving water temperature, DHW tank temperature).

d

 MENU STRUCTURE/BACK

▪ Opens the menu structure (when you are on a home page).
▪ Goes  a  level  up  in  the  menu  structure  (when  you  are

navigating in the menu structure).

▪ Goes  back  1  step  (example:  when  you  are  programming  a

schedule in the menu structure).

e

 

 

 

 NAVIGATING/CHANGING SETTINGS

▪ Navigates the cursor on the display.
▪ Navigates in the menu structure.
▪ Changes settings.
▪ Selects a mode.

f

 OK

▪ Goes to the next step when you are programming a schedule

in the menu structure.

▪ Confirms a selection.
▪ Enters a submenu in the menu structure.
▪ Switches  between  displaying  actual  and  desired  values,  or

between displaying actual and offset values (if applicable) on
the home pages.

▪ Enables you to activate or deactivate child lock if pressed for

more than 5 seconds on a home page.

▪ Enables  you  to  activate  or  deactivate  a  function  lock  if

pressed  for  more  than  5  seconds  in  the  main  menu  of  the
menu structure.

INFORMATION 

If you press 

 or 

 while changing settings, the changes

will NOT be applied.

4.2.2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Unit is operating.

Desired room temperature = preset value (Comfort;
daytime).
Desired room temperature = preset value (Eco;
nighttime).
▪ On  the  room  temperature  home  page:  Desired

room  temperature  =  according  to  the  selected
schedule.

▪ On  the  DHW  tank  temperature  home  page:

DHW tank mode = Scheduled mode.

DHW tank mode = Reheat mode.

 

DHW tank mode = Sch reheat mode.

At the next scheduled action, the desired temperature
will increase.
At the next scheduled action, the desired temperature
will NOT change.
At the next scheduled action, the desired temperature
will decrease.
The preset value (Comfort or Eco) or scheduled value
is temporarily overruled.
The system will produce domestic hot water for the
indicated number of persons.
The DHW tank booster mode is active or ready to be
activated.
Quiet mode is active.

Holiday mode is active or ready to be actived.

Child lock mode and/or function lock mode is active.

An external heat source is active. Example: Gas
burner.
The disinfection mode is active.

A malfunction occured. You can press 

 to display

more information about the malfunction.
Weather-dependent mode is active.

User permission level = Installer.

Defrost/oil return mode is active.

Hot start mode is active.

 

Summary of Contents for Belaria compact SRM 11-16/260

Page 1: ...4 Inneneinheit BelariaSRM 6 8 Inneneinheit BelariaSRM 11 16 Inneneinheit Belaria compact SRM 4 180 IE Belaria compact SRM 6 8 260 IE Belaria compact SRM 11 16 260 IE Subject to change 4 211 876 00 11...

Page 2: ...the contact helpdesk number 21 7 Troubleshooting 21 7 1 Overview Troubleshooting 21 7 2 To check the error history 21 7 3 Symptom You are feeling too cold hot in your living room 21 7 4 Symptom The wa...

Page 3: ...Detailed step by step instructions and background information for basic and advanced usage CD DVD in the box of the indoor unit Latest revisions of the supplied documentation may be available on the...

Page 4: ...in the menu structure Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between displaying actual and offset values if applicable on...

Page 5: ...n ON Then Room temperature control Main additional leaving water temperature control is automatically turned ON If you turn ON Then Main additional leaving water temperature control Room temperature c...

Page 6: ...r settings Allowed operation mode 2 Select a month and press 3 Select Heating only Cooling only or Heating Cooling and press Typical automatic changeover restrictions When Restriction During cold seas...

Page 7: ...Preset values and schedules on page 15 Leaving water temperature of the main zone To control the leaving water temperature of the main zone you can do the following You can Location Read out the desi...

Page 8: ...18 C Desired temperature When you are away During the night Schedule 07 00 Comfort You are at home Desired temperature preset value Comfort heating 09 00 Eco You are away Desired temperature preset va...

Page 9: ...eduled 20 C Advantage You save energy because you do NOT heat the room unnecessary and by the time you come home the room is warm again Using the leaving water temperature home pages main additional I...

Page 10: ...to the DHW tank temperature home page Tank 2 Check which icons are displayed If is displayed Then the DHW tank mode Reheat mode Scheduled mode Scheduled reheat mode 4 5 2 Reheat mode In reheat mode t...

Page 11: ...pump schedule to determine when to turn ON and OFF the pump When turned ON the pump runs and makes sure hot water is instantly available at the tap To save energy only turn ON the pump during periods...

Page 12: ...tivate the DHW tank booster mode energy saving 4 5 6 Using the DHW tank booster mode About the DHW tank booster mode You can use the DHW tank booster mode to immediately start heating up the water to...

Page 13: ...re on page 6 Using holiday mode typically consists of the following stages 1 Configuring the holiday for one of the following situations Situation Then You stay at home during your holiday You have to...

Page 14: ...an do the following 1 Deactivate the holiday mode 2 When you go away again activate the holiday mode again Advantage You do NOT have to change your schedule or holiday configuration easy 4 6 3 Reading...

Page 15: ...Function lock Locks a specific function to prevent people from changing its settings Possible function locks Lock If active people cannot Room On OFF Turn ON or OFF the room temperature control LWT On...

Page 16: ...c hot water tank Booster heater allowance Program when the booster heater can operate Example Only allow the booster heater to operate during the night Control Possible actions Quiet mode Program when...

Page 17: ...ned 1 User defined 2 or User defined 3 and press 3 Change the name and press Example MyWeekSchedule 4 7 4 Predefined schedules Room temperature leaving water temperature main Desired temperature Prese...

Page 18: ...0 11 12 4 7 6 Predefined schedules DHW tank temperature a Start production of domestic hot water Desired DHW tank temperature Preset value Storage comfort b Start production of domestic hot water Desi...

Page 19: ...tors Operation modes Running hours Version Display Temperature lock Set schedules Preset values User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Ope...

Page 20: ...c hot water control A 4 Setting Default Fill in Setpoint mode 2 Scheduled only Setpoint readout type 0 Temperature Maximum setpoint Depends on model INFORMATION It is recommended NOT to use the select...

Page 21: ...ation Error handling Contact helpdesk number 7 Troubleshooting 7 1 Overview Troubleshooting If a malfunction occurs is displayed on the home pages You can press to display more information about the m...

Page 22: ...ble for a certain product or domain Service company Qualified company which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain...

Page 23: ......

Page 24: ...sterreich Hoval Gesellschaft mbH Hovalstrasse 11 A 4614 Marchtrenk Telefon 050 365 0 Telefax 050 365 5005 www hoval at info hoval at Marchtrenk Hovalstrasse 11 4614 Marchtrenk Tel 050 365 5550 Fax 050...

Reviews: