4 Operation
User reference guide
16
Bela08+16I3 + Belar08+16I3
Hoval BelariaSRM and Hoval Belaria compact SRM
4P330441-1 – 2012.11
4 211 876 / 00 – 11/12
Control
Preset value
Where used
Eco
▪ Room temperature home
page (
and
) if user
profile = Detailed
LWT main
Comfort
Main leaving water
temperature schedules
Eco
Tank
temperature
Storage comfort
DHW tank temperature
schedule if DHW tank mode
=
▪ Scheduled
▪ Sch reheat
Storage eco
Reheat
DHW tank temperature
schedule if DHW tank mode
= Sch reheat
Quiet level
Used when quiet mode is
set to On.
4.7.2
Using and programming schedules
About schedules
Depending on your system layout and installer configuration,
schedules (predefined and/or user
‑
defined) for multiple controls may
be available.
You can:
▪ Select which schedules you currently want to use.
▪ Program your own schedules if the predefined schedules are not
satisfactory. The actions you can program are control specific.
Possible actions per control
Control
Possible actions
Room temperature Program when to heat up or cool down a
space:
▪ Comfort (preset vaule)
▪ Eco (preset value)
▪ [Custom temperature]
Main leaving water
temperature
Additional leaving
water temperature
Program when the additional leaving water
temperature is turned ON and OFF.
(Only for
BelariaSRC
and
BelariaSR
in
combination with
an optional
domestic hot
water tank)
DHW
tank
temperature
Program when to heat up the DHW tank. The
possible actions depend on an installer setting.
Possible actions 1:
▪ Storage comfort (preset value)
▪ Storage eco (preset value)
▪ Storage stop
(a)
Possible actions 2:
▪ [Custom temperature]
▪ Storage stop
(a)
(Only for
BelariaSR
in
combination with
an optional
domestic hot
water tank)
Booster
heater
allowance
Program when the booster heater can operate.
Example: Only allow the booster heater to
operate during the night.
Control
Possible actions
Quiet mode
Program when the unit has to use which quiet
mode level:
▪ Level 1
▪ Level 2
▪ Level 3
▪ OFF
(Only for field
supplied
domestic hot
water pump for
secondary return)
Domestic hot water
pump
Program when the domestic hot water pump is
turned ON and OFF.
(a)
Storage stop (to stop heating, even if the desired temperature is not
reached yet; example: if electric tariffs are higher during the day, you
can program a stop at 06:00)
To select which schedule you currently want to
use
1
Go to [5]:
> Select schedules.
2
Select for which control you want to use a schedule.
Example: [5.1] Room temperature.
3
Select for which operation mode you want to use a schedule.
Example: [5.1.1] Heating.
4
Select a predefined or user
‑
defined schedule and press
.
To program a schedule
1
Go to [7.3]:
> User settings > Set schedules.
2
Open an empty, predefined or user
‑
defined schedule.
3
Change it.
4
Save it.
Guidelines when programming
: 00
:
0 7
OK
C l e a r d a y s c h e d u l e
D e l e t e l i n e
C o p y d a y
S a v e s c h e d u l e
S e l e c t
S c r o l l
S e t h e a t i n g s c h e d u l e
Mon
C o m f o r t
You can:
▪ Delete lines from the schedule
▪ Clear a day schedule
▪ Copy from one day to others
Usage example: You work in a 3-shift system
If you work in a 3-shift system, you can do the following:
1
Program 3 room temperature schedules in heating mode and
give them appropriate names.
Example: EarlyShift, DayShift and LateShift
2
Select the schedule that you currently want to use.
4.7.3
Schedules: Example
INFORMATION
The procedures to program other controls are similar.
In this example:
▪ Room temperature schedule in heating mode
▪ Monday = Tuesday = Wednesday = Thursday = Friday
▪ Saturday = Sunday
To program the schedule
1
Go to [7.3.1.1]:
> User settings > Set schedules > Room
temp. > Set heating schedule.
Summary of Contents for Belaria compact SRM 11-16/260