8.916-832.0 • HOTSY 5700/5800 NG Service Manual • Rev. 10/09
9
PRESSURE
W
ASHER
SER
VICE
MANU
AL
OPTIONAL — WATER INLET SOLENOID
A water inlet solenoid can be added to the machine that
will open only when the machine is running or in standby.
The solenoid closes when the machine is off to prevent
possible water overflow when unattended.
Installation
• Connect a 24V/AC normally closed solenoid on the
water inlet, contact local Hotsy dealer for solenoid
options.
• Connect solenoid to the remote terminal using
16 ga minimum wire
• Wire solenoid to remote terminal according to
figure below
Before powering up machine, fill float tank to prime the
system.
Detergent Solenoid Wiring Schematic
WATER INLET