1800 SERIES PRESSURE WASHER
OPERATOR’S MANUAL
9
Hotsy 1800
•
97-6244 Rev. 7/06
Water supply
Connect water supply hose to water inlet on float tank. The
water faucet and supply hose must be capable of providing
a minimum of 6.0 gallons per minute (GPM).
fuel supply
CAUTION: Have a qualified gas serviceman install and
service your equipment.
WARNING: Gas line supply pressure must not exceed
14 water column inches (.50 PSI).
IMPORTANT: Gas line must be provided with a shut
off valve.
IMPORTANT: The gas supply must be able to supply
a minimum of 560,000 BTU/HR at the machines rated
manifold pressure.
Consult building codes for installation requirements.
For proper and safe machine operation, we recommend
that a licensed contractor be consulted for machine
installation.
natural Gas fuel
Have a qualified gas serviceman install the natural gas
fuel supply line to the machine. See
figure 6
for location
of gas inlet.
Gas valve
The ideal incoming gas pressure is 11 w.c.i. (water column
inches) minimum 6 w.c.i., maximum 14 w.c.i. or 1/2 psig.
The correct operating manifold pressure for natural gas
is 3.5 w.c.i. The operating manifold pressure for propane
gas is 11 w.c.i. The gas valve pressure regulator can be
adjusted between 3 and 4 w.c.i. natural gas or 6 and 11
w.c.i.for propane.
The gas pressure coming out of the regulator and going
to the burner ring has been factory set. You should not
readjust the burner ring gas pressure. If you replace your
gas valve, you will need to adjust the new valve. Refer to
your machine’s
specification plate
for the correct pressure
setting. Follow the installation and adjustment instructions
provided with your replacement valve.
electrical
WARNING: Make sure all switches and controls
are in the OFF position prior to connecting electrical
supply.
WARNING: DO NOT stand in water while connecting
and disconnecting electrical supply.
WARNING: Always disconnect power before servicing
your pressure washer.
IMPORTANT: Consult local building codes for exact
electrical requirements. Licensed contractors may be
required.
IMPORTANT: All wiring must be of proper voltage and
amperage rating and conform to applicable codes.
IMPORTANT: This machine must be electrically ground-
ed. LA MACHINE DOIT ÊTRE MISE À LA TERRE.
Grounding instructions:
Make sure all switches and
controls are in the OFF position prior to connecting elec-
trical supply. Do not stand in water while connecting and
disconnecting electrical supply. If it should malfunction or
break down, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock. The
product must be connected to an appropriate power source
that is properly installed and grounded in accordance with
all local codes and ordinances.
DANGER: Improper connection of the equipment
grounding conductor can result in a risk of electro-
cution. Check with a qualified electrician or service
personnel if you are in doubt as to whether the
outlet is properly grounded.
The 1800 Series are not provided with a power cord.
These models must be connected to a grounded, metal,
permanent wiring system. Refer to wire diagrams for proper
incoming power connections.
extension cords:
Do not use extension cords with this
equipment.
WARNING: To reduce the risk of electrocution, keep all
connections dry and off the ground.
operation
before starting
1. Read all manuals provided with this pressure washer.
Become familiar with location and function of all
operating and safety controls.
WARNING: Check hoses, fittings, wand, trigger gun
and fuel connections daily for signs of wear, cracks
and looseness, and replace as required.
Figure 6 - Gas Valve and Regulator Side View
outlet port
inlet port