Copyright 2013 HotSpot Energy
FITTING THE INSTALLATION PLATE
NOTE:
Fitting The Installation Plate
Ensure that the mounting wall is strong and solid
enough to prevent vibration.
1. Fit the installation plate horizontally on structural
parts of the wall with spaces around the installation
plate. See figure 3
2. If the wall is made of brick, concrete or the like, drill
eight (8) 5mm diameter holes in the wall and insert
anchor clips for appropriate mounting screws.
3. Fit the installation plate on the wall with eight (8)
type A screws.
Fit the Installation Plate and drill holes in the wall
according to the wall structure and corresponding
mounting points on the installation plate. The
installation plate is provided with the machine.
(Dimensions are in mm unless otherwise stated)
For correct orientation of Installation plate see
figure 4.
DRILL A HOLE IN THE WALL
1. Determine left and right side hole positions according
to the installation plate. The hole center is obtained by
measuring the distance as shown in the diagram figure
2. Drill the piping plate hole with 65mm hole saw drill
bit.
3. Drill the piping hole at either the right or the left
side. The hole should be slightly slanted to the outdoor
side for condensate water drainage.
See figure 5
4 Always use conduit when drilling through metal grid,
metal plate or the like.
Figure 3
Figure 4
Figure 5
7