14 of 31
Service Manual UK
Whirlpool UK Appliances
English
N
Motor
1.
Remove the back panel (B).
2.
Remove the bolts securing the motor and support the motor.
3.
Pull the motor forward of the locating pegs and lift clear.
O
Pump
1.
Remove the plinth.
2.
Using suitable protection, tilt the machine backwards and support.
3.
Remove the pump fixing screws and disconnect the hoses and wiring.
P
Power Module
1.
Remove the back panel (B).
2.
Remove 2 screws securing the module support to the cabinet.
3.
Disconnect the wiring.
4.
Lift module and support clear.
Q
Bearings
Note: The drum bearing assembly comes as a complete unit, therefore the bearings cannot be
replaced. A new drum/tank assembly will need to be fitted if the bearings have failed.
R
Door Seal Retainer to Outer Case
1.
The door seal is fixed to the cabinet front panel by a wire clamp and a small spring. The spring is
usually at the bottom of the door.
2.
Carefully attach a small screwdriver to one of the ears of the spring. By stretching the spring the
wire band can be removed.
S
Shock Absorbers
1.
Using suitable protection lean the appliance onto
one side.
2.
Remove the 10 mm nut securing the shock
absorber to the cabinet.
3.
Push the shock absorber on the rod until it comes
out of the cabinet.
4.
Remove the plastic expansion rivet fixing the shock
absorber to the tank. (Remove the pin first to make
removal easier.)