![Hotpoint PH 640 M/HA Instructions For Use Manual Download Page 17](http://html1.mh-extra.com/html/hotpoint/ph-640-m-ha/ph-640-m-ha_instructions-for-use-manual_2167111017.webp)
GB
17
Burner and nozzle specifications
Table 1 Liquid Gas Naturale Gas
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
20
17
25
28-30
20
35
37
25
45
Fast (Large) (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
Semi-FishBurner (SP)
Supply
pressures
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
100
100
75
55
130
-
3.00
2.60
1.65
1.00
3.25
1.50
Nom.
Red.
0.70
0.70
0.40
0.40
1.50
0.70
By-pass
1/100
(mm)
41
41
30
30
60
41
(1)
39
39
28
28
61
39
Nozzle
1/100
Flow*
g/h
(mm)
***
86
80
64
50
91
60
Nozzle
1/100
Flow*
l/h
(mm)
116
110
96
71
133
88
286
248
157
95
309
143
218
189
120
73
236
109
**
214
186
118
71
232
107
*
At 15°C and 1013 mbar - dry gas
***
Butane P.C.S. = 49.47 MJ/Kg
**
Propane P.C.S. = 50.37 MJ/Kg
Natural P.C.S. = 37.78 MJ/m
3
Table 1 (For Hungary) G 20 G 25.1 G 30
Fast (R)
Reduced Fast (RR)
Semi Fast (Medium) (S)
Auxiliary (Small) (A)
Triple Crown (TC)
Semi-FishBurner (SP)
Supply pressures
At 15°C and 1013 mbar-dry gas
P.C.I. G30
122,8 MJ/m
3
P.C.I. G20
35,9 MJ/m
3
P.C.I. G25.1
30,9 MJ/m
3
25 mbar
25 mbar
Burner
Thermal
Power kW
2,90
2,45
1,60
0,90
3,15
1,50
Nozzle
1/100 (mm)
116
110
96
71
133
88
Thermal
Power kW
2,25
1,90
1,25
0,65
2,45
1,15
Nozzle
1/100 (mm)
116
110
96
71
133
88
30 mbar
Thermal
Power kW
2,70
2,30
1,50
0,90
2,90
1,40
Nozzle
1/100 (mm)
86
80
64
50
91
60
R
S
S
A
R
S
S
A
RR
A
S
TC
TC
S
TC
PH 940 M/HA
PH 941 M/HA
PH 941 MSTV/HA
PH 930.../HA
PH 940 MS/HA
PH 941 MS/HA
PH 941 MSTV GH/HA
TC
S
RR
A
RR
S
A
TC
SP
TC
S
RR
A
PH 941 MSTB/HA
PH 960 MST/HA
PH 940 MST/HA
PH 941 MSTB GH/HA
PH 960 MST GH/HA
PH 960 MST R/HA
!
The hob can only be installed above built-in ovens with a cooling ventilation system.