32 of 45
Indesit
Company
Service Manual UK
English
DOOR SWITCH ADJUSTMENT
When a door switch is removed or replaced, ensure it is adjusted as per the instructions below. Failure
to do this can result in the turntable rotating continuously.
1.
Ensure the door latch depresses the red microswitch lever. Check both switch assemblies.
If it does not make the lever, unscrew the assembly and move it forwards until it does.
2.
Test ALL appliance functions and carry out microwave leakage test.