SPACE FOR FIXING
The cooker is of type X with regard to protection against overheating of
surrounding surfaces as defined in BS EN60 335 - 2 - 6: 1991
The cooker can be close fitted below hotplate level. This requires a minimum
distance of 600mm between cupboard units of hotplate height.
When installing next to a tall cupboard, partition or wall, for a minimum distance
of 400mm above hotplate level, allow a side clearance of at least 65mm.
The diagram below illustrates the minimum clearance between the cooker and
adjacent walls, cupboards etc.
The wall behind the cooker between the hotplate and 450mm above, and the
width of the cooker, must be a non-combustible material such as ceramic wall
tiles.
If the cooker is to be fitted close to a corner on the left hand side, ensure that
there is a clearance of at least 50mm to allow the main oven door to open fully
for when removing oven shelves.
COOKER HOODS
If a cooker hood is to be installed, refer to the cooker hood manufacturers’
instructions regarding fixing height.
30
INSTALLATION INSTRUCTIONS
65 m
600 mm
750mm
min