Non-Programmable Single Stage Thermostat 

                                       

Reference  No.:

 

HTW-ST01-A 

 

                                                         

 

- 3 -

                                                                            Version 2019-1.0                                                                                             

Tip: 

Worried  about  having  your  wires  falling  into  your  wall? 

Keep the wires secure by wrapping them around a pencil.

 

4. Identify jumper wire 

On your old thermostat, if…

 

Then, on your new thermostat…

 

Terminal RC and RH are connected with a jumper wire

 

Leave the jumper wire in its place

 

There’s only one R wire (RC, RH, R or R5) coming out of the wall

 

Leave the jumper wire in its place

 

Terminal RC and RH (or 5 or R5) are NOT connected by a jumper wire

 

Remove the jumper wire between RC and RH

 

For terminal 

Y

 and 

W

If you have a heat pump with reversing valve, connect Y and W with a jumper wire on your new thermostat. 

 

5.Remove old thermostat base 

With all of your wires disconnected and properly labeled, you may now safely remove the thermostat base from your wall. 

 

************************Mounting and Wiring Your New Thermostat************************ 

1.Install new thermostat base 

 

2.Connect wires to corresponding terminal blocks 

Match each labeled wire to it’s corresponding terminal on the mounted thermostat base. Insert each labeled wire into the hole of 

it’s matching terminal, and using the screwdriver, tighten the screw on the terminal block securely. 

 

3.Set switch and advanced wiring

 

 

 

 

 

4.Install the batteries and attach front cover 

Install 2*AA alkaline batteries and push the front cover on to the thermostat base until it’s secure. 

5.Turn on power 

Turn on your power at the source. 

Congratulations!   

You’ve completed the thermostat installation process 

 

 

Identify and label each wire

 

IGNORE WIRE COLORS: 

Use  terminal  screw  designations 

to identify wires.

 

Mount  your  new  thermostat  base  using  screws.  Drill  holes  and  insert  wall 

anchors to secure the thermostat base to the wall, if necessary.

 

 

If you have either a gas or oil furnace, set the switch to GAS. 

If you have an electric furnace, set the switch to ELEC. 

 

Summary of Contents for HTW-ST01-A

Page 1: ...nent user setting retention during power loss No batteries are required Apply to 24VAC or 2 AA alkaline batteries power supply Air Filter change Indicator Low Battery Indicator Temperature calibration 4 or 5 wire compatible C is optional for non heat pump systems Manual Changeover Fan Switch Easy operation friendly Mercury Free Environmentally Safe Built in compressor protection Power Supply 20VAC...

Page 2: ...your screwdriver carefully unscrew one wire at a time from the terminal block and attach the corresponding wire label sticker Please note that not all terminals may be used and that there s no standard color code for thermostat wires so your wire colors may vary For your reference we ve included a terminal label reference chart as below to help you connect the wires in your old thermostat to your ...

Page 3: ...t base from your wall Mounting and Wiring Your New Thermostat 1 Install new thermostat base 2 Connect wires to corresponding terminal blocks Match each labeled wire to it s corresponding terminal on the mounted thermostat base Insert each labeled wire into the hole of it s matching terminal and using the screwdriver tighten the screw on the terminal block securely 3 Set switch and advanced wiring ...

Page 4: ...position If the heating system has a standing pilot be sure to light it Press to adjust thermostat setting room temperature The heating system should begin to operate Press to adjust temperature setting below room temperature The heating system should stop operating Cooling system Move SYSTEM switch to COOL position Press to adjust thermostat setting below room temperature The blower should come o...

Page 5: ...ll show dEF blink Child Lock Quickly and simultaneously press the and three times to lock the temperature adjustment and again to unlock RESET function This function can help operator to recovery system when fault happened display out of order or system halted Please use a pin to insert in button RESET hole till sounded click then loosen it Move the SYSTEM switch to the OFF position then press and...

Page 6: ...increments Selection of 00 WILL CANCEL THIS FEATURE When Filter Alarm is displayed you can clear it by pressing the and buttons This resets the timer and starts counting the days until the next filter change 4 Select compressor lockout delay 0 1 2 3 4 5 To protect the compressor from short cycling you can select compressor off time cycle between 0 to 5 minutes When the thermostat compressor time d...

Reviews: