Weekly Programmable Wireless LCD Room Thermostat 

Reference No.:

HTW-91-WT416-X8

 

 

                                                         

 

- 4 -

                                                                            Version 2018-1.0                                                                                             

    2

nd

 

Sender(HTW-91-WT410 Controlling Panel)

 

    At the state of switching off, press and hold            button for some secs to enter into Learn. In this 

case,  the  display  of  room  temperature  is  “

rE

”;  after  that,  press            button  quickly,  Learn  is 

matching.  If  Learn  is  successful,  the  display  of  Room  Temperature  should  be  “

OH

”;  if  not,  the 

display is “

Er

”, please Learn again. 

3

rd

 

Recipient(RF Receiver)

 

Press the Learn button once finally to exit Learning Mode after “OH” displays. 
 
 
 
HTW-91-WT410 Under switch off status, please press and hold            button for 3 seconds 

1

UU

UUU

Remark:  Those  parameters  can  be  set  under  Manual  Mode  and  Automatic  Programmable  Mode.  In  other  modes, 

parameters are defaulted. 

 
 

      If there are any errors happened, error code will be displayed 

 

Er1   

 

Internal Sensor 

 

Er3   

 

External Sensor 

 

Er5   

 

RF Signal Transmitting 

It might occur that some or all of them happen at a once. Please figure out by values.       

Code 

Parameters 

Operated by + / - button 

Temp Calibration 

-9

~+9

 

Sensors 

0:Single Internal Sensor activate 

1:Internal and External sensors activate 

Buttons Lock/unlock 

0

Except On/off button, other buttons are locked 

1

All buttons are locked 

(To unlock by            pressing the buttons of           

simultaneously 

4

1

 

Frost Projection    activation   

0

Off        1:On 

5

1

 

Setpoint 

Range 

of 

Frost 

Protection 

5

~15

(When it is activated,if room temperature is lower 

than this setpoint, heating equipments will open up 

automatically. 

6

1

 

Setpoint 

Range 

of 

Overheating Protection 

35

~70

(When room temperature is higher than this 

setpoint, heating equipments will be cut off    automatically. 

7

1

 

High Temperature Differential 

range 

 

between 

room 

temperature and setpoint   

0

~9

(when the room temperature is higher than 

temperature of setpoint plus this deferential setpoint, heating 

equipment is cut off automatically)   

8

1

 

Low  Temperature  Differential 

range 

 

between 

room 

temperature and setpoint   

0

~9

  (when the room temperature is lower than 

temperature of setpoint minus this deferential setpoint, heating 

equipment is activated automatically) 

Parameter Setting 