background image

 
 

Weekly Programmable Wireless LCD Room Thermostat 

Reference No.:

HTW-91-WT416-X8

 

 

                                                         

 

- 3 -

                                                                            Version 2018-1.0                                                                                             

14.Modes selecting or Time setting,etc. 

        Modes:Selecting Automatic Mode, Comfort Mode, Energy Saving Mode and Frost   

Protection Mode   

       

Time Setting 

  Press and hold this button for 3 sec, increase or decrease value by 

              buttons; sequence from Hour, Minute to Week day via pressing            button. 

15.

 

Temperature up, or other parameters setting 

In case of internal and external sensors are selected, press + button for 3 sec, Setpoint 
is displaying external sensor’s temperature; after 3 sec, it returns to setpoint.   

16.

 

5+1+1 Programmable setting 

Press            button and program setpoints and time zones accordingly.Increase   

Mon to Fri 

        1

PPPPPP

st

P PPP PP

 time setting, 1

PPPPPP

st

PP PPP P

 setpoint setting......6

PPP PPP

th

PPP PPP

 time setting, 6

PPPPPP

th

PPP PPP

 setpoint setting

 

Saturday 

          1

PPPPP P

st

PPP PPP

 time setting, 1

PPPPPP

st

P PPPP P

 setpoint setting......6

PPPP PP

th

PPP PPP

 time setting, 6

PPPPPP

th

PPP PPP

 setpoint setting 

Sunday

              1

PP PPP P

st

PPPP PP

 time setting, 1

PPPPPP

st

P PPPP P

 setpoint setting......6

PPPP PP

th

PPP PPP

 time setting, 6

PPPPPP

th

PPP PPP

 setpoint setting 

Decreasing or Increasing value by 10 mins by                buttons.           

       

Ex-factory Settings

 

 

         
 
         

17.

 

Temperature down, or other parameters setting 

18.

 

On/off button 

19.

 

Red Power LED 

20.

 

Green RF signal LED     

21. 8 Zone Valves Working Status: when the 

corresponding zone valve is working, LED is on;   

        When LED is off, its corresponding valve isn’t working.

 

22. 8 IP Learn buttons 

IP Learn button 

Normal State

(steady connection between Sender and Recipient)

 

Green LED keeps ON when the RF connection is working fine. But, When the RF signal is   
transmitting, Green LED will flash ONCE in each 15 minutes; If Heating equipments is 
connected, Red LED is ON 
 
 

 

How to Learn

 

      1

st

 

Recipient(RF RECEIVER)

 

      Press and hold Learn button for some secs, Green LED will keep flashing. When the Learn is done 

and successful, Red LED is on and Green Led stop flashing.   

              Weekday 

     

Time Zone 

1~5 

Mon~Fri 

Sat. 

Sun. 

1    06:00~08:00 

20

 

20

 

20

 

2    08:00~11:30 

10

 

20

 

20

 

3    11:30~13:30 

18

 

20

 

20

 

4    13:30~17:00 

10

 

20

 

20

 

5    17:00~22:00 

20

 

20

 

20

 

6    22:00~06:00 

18

 

18

 

18

 

Integrate Panel with Receiver 

Reviews: