background image

Page 16

WATER HEATERS

MADE IN THE U.S.A.

ECR International

P.O. Box 4729 • Utica, NY 13504-4729

www.ecrinternational.com

GENERAL CONDITIONS

Hot Line Water Heaters, ECR International, warrants that the

Hot Line tank shall be free of defects in material and workman-

ship during normal use and service for as long as the original

residential purchaser owns the home in which the unit was orig-

inally installed. For the purposes of this Limited Warranty, res-

idential purchaser is defined as the owner of a single family

home in which the purchaser resides on a permanent basis.

If at the time of a request for warranty the original residential

purchaser can not provide a copy of the original sales receipt,

deed, or equivalent document, then the warranty period for the

Hot Line shall be seven (7) years from the date of manufacture

of the unit. The Limited Warranty on the tank shall be reduced

to a period of three (3) years if the purchaser is a business, part-

nership or corporation, or if the water heater is used for a com-

mercial or multi-family residential property application.

Should a leak develop within this Limited Warranty period due

to defective materials or workmanship and such leak having

been verified by an authorized company representative, ECR

International will repair the unit or furnish a replacement Hot

Line heater or the nearest comparable model available at the

time of replacement.

ECR International shall not be liable for any water damage

arising directly or indirectly from any defect in the water

heater or component part(s) or from the use thereof or any

service call not involving malfunction or defects in materials or

workmanship.

THIS WARRANTY IS VOID AND SHALL NOT APPLY IF:

1) The unit is not correctly installed according to the installa-

tion instructions provided with the unit.

2) The residential indirect-fired water heater is installed in

buildings other than one or two family dwelling units, unless

the buildings contain individual indirect-fired water heaters

for each dwelling unit.

3) The indirect-fired water heater is operated at water tem-

peratures of more than 125 degrees F. and water pressure of

more than 150 PSI.

4) The failure or malfunction results from improper or negli-

gent operation, accident, abuse (including freezing), misuse,

unauthorized alteration, improper repair or maintenance,

excessive pressure or leaks at water connections or any other

similar cause.

5) The failure or malfunction results from failure to keep the

unit full of potable water, free to circulate at all times; or fail-

ure due to water sediment or scale deposits.

6) The original serial number of the water heater cannot

readily be determined.

7) ECR International Hot Line is installed outside of the

United States or Canada.

8) ECR International Hot Line is repaired or altered without

prior written approval of ECR International and this serv-

ice adversely affects the product’s reliability.

9) The malfunction or repairs result from the use of ECR In-

ternational Hot Line for purposes other than that for which it

was designed or any malfuction resulting from flood, fire,

wind or lightning.

ECR International will provide, under the Limited Warranty,

only a replacement water heater, repairs, or parts for defec-

tive units. The Limited Warranty does not cover any compo-

nent of ECR International Hot Line that has to be replaced

during the warranty period as a result of reasonable wear

and tear, labor costs, shipping charges, delivery expenses,

nor administrative fees incurred by the customer in removing

or reinstalling the Hot Line.

In no event shall ECR International be liable for incidental or

consequential damages. Some states do not allow the exclusion

or limitation of incidental or consequential damages, so the

above limitation or exclusion may not apply to you.

In order to gain coverage under this Limited Lifetime Warran-

ty, the consumer is required to fill out and mail the Limited

Warranty registration card provided with the unit by regis-

tered mail within 30 days of purchase.

To submit a warranty claim, contact the dealer who sold the

Hot Line covered by this Limited Warranty. If the dealer can-

not be located, contact ECR International at the address

shown below. Whenever any inquiry or service request is

made, please include the Hot Line model number, serial num-

ber, date of installation, and dealer’s name.

No warranty, express or implied, other than the foregoing Lim-

ited Warranty is authorized by ECR International and no rep-

resentative of ECR International or of the manufacturer of any

component has the authority to amend, extend, modify, enlarge

or contract the foregoing Limited Warranty and the disclaimers

of the Limited Warranty in any manner whatsoever.

SECTION VIII: WARRANTY

LIMITED LIFETIME WARRANTY

Summary of Contents for HL119SK

Page 1: ...that commonly reduces the life of other in direct water heaters 3 Steel coil increases heat transfer for faster recov ery and the luxury of never running out of hot water 3 Coils and tank lining are...

Page 2: ...rvice This unit must be installed by licensed or authorized installers or technical personnel that service water heating equipment The heater must be installed in accordance with all local codes and o...

Page 3: ...Section I Specifications 4 Section II General Information 6 Section III Pre Installation 8 Section IV Installation 10 Section V Maintenance 13 Section VI Troubleshooting 14 Section VII Parts List 15...

Page 4: ...etting for normal residential use is 120 F ECR recommends a tempering valve or anti scald valve be installed and used according to the manufacturer s directions to prevent scalding HL30SK 22 35 3 4 27...

Page 5: ...78 88 000 190 96 000 202 104 000 214 111 000 HL80SK 188 76 000 212 91 000 224 98 000 221 97 000 233 104 000 245 112 000 257 119 000 HL119SK 220 76 000 244 91 000 256 98 000 253 97 000 265 104 000 277...

Page 6: ...provides limited control for domestic hot water temperature The proper temperature setting for domestic hot water use is 120 F 49 C If hotter water is required a tempering device or anti scald device...

Page 7: ...r system When hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the faucet at...

Page 8: ...th 180 F and 200 F boiler water To determine the appropriate circulator for your system follow these three steps 1 Calculate the pressure drop of all straight pipe and fittings on the supply and retur...

Page 9: ...inimum coil output assume coil output boiler output listed in Tables 2 and 3 is not met the output first hour rating of the water heater will not be met at the selected flow rate To approximate the re...

Page 10: ...be minimized A flow check valve must be installed on the return line All piping to the inlet cold and outlet hot domestic water connections should be new copper with a minimum size of 1 2 ID for model...

Page 11: ...IV INSTALLATION cont CHECK VALVES ZONE CIRCULATORS ISOLATION VALVES ADDITIONAL ZONES INDIRECT CIRCULATOR INDIRECT WATER HEATER TO HEATING ZONE AIR SEPARATOR AIR VENT EXPANSION TANK COLD WATER INLET BO...

Page 12: ...the indirect calls for heat the indirect coil tank heater circulator must start rather than opening a zone valve the system circulator stays off and the boiler must light to reach high limit WIRING NO...

Page 13: ...nd at least yearly once a time interval for inspection has been developed It is recommended to check the rod s six months after the heater is installed If the anode rod had reduced in size by two thir...

Page 14: ...k power supply Replace as necessary Faulty tank aquastat Replace aquastat Boiler cycles more than 5 times per day during hotest months Excessive demand Reduce demand or consider larger tank Faulty aqu...

Page 15: ...HL50SK 3 HL80SK 3 HL119SK 5 Leak Detector Fitting HL30SK HL40SK 5 Leak Detector Fitting HL50SK HL80SK HL119SK 6 ST00601 1 T P Relief Valve 3 4 LL100XL HL30SK HL40SK HL50SK 6 ST01001 1 T P Relief Valve...

Page 16: ...e unauthorized alteration improper repair or maintenance excessive pressure or leaks at water connections or any other similar cause 5 The failure or malfunction results from failure to keep the unit...