Hot Shot HS-360 Owner’s Manual R2.0 | 5
READY TO PROGRAM YOUR CONTROLLER NOW?
Novus 480D setting ramp and soak times, temps and events.
Novus 480D setting ramp and soak times, temps and events.
The oven comes with a factory installed USB port for programming the controller via a computer. Note:
Disconnect oven from power source before plugging in USB.
Press and hold the “P” button till PTOL appears, the use the “P” button to scroll thru parameter group.
GROUP
PARAMETER
PSPO
starting temp (control temp starting pt)
Pt1
time 1 (set desired temp)
PSP1
temp 1 (set desired temp)
PE1
event 1 (off or A-1 for alarm)
Pt2
time 2 (desired temp)
PSP2
temp 2 (set desired temp)
PE2
event 2 (off or A-1 for alarm)
Pt3
time 3 (set desired time)
PSP3
temp 3 (set desired temp)
PE3
event 3 (off or A-1 for alarm)
Pt4
time 4 (set desired time)
PSP4
temp 4 (set desired temp)
PE4
event 4 (off or A-1 for alarm)
Pt5
time 5 (set desired time)
PSP5
temp 5 (set desired temp)
PE5
event 5 (off or A-1 for alarm)
Pt6
time 6 (set desired time)
PSP6
temp 6 (set desired temp)
PE6
event 6 (off or A-1 for alarm)
Pt7
time 7 (set desired time)
PSP7
temp 7 (set desired temp)
PE7
event 7 (off or A-1 for alarm)
GROUP
PARAMETER
Pt8
time 8 (set desired time)
PSP8
temp 8 (set desired temp)
PE8
event 8 (off or A-1 for alarm)
Pt9
time 9 (set desired time)
PSP9
temp 9 (set desired temp)
PE9
event 9 (off or A-1 for alarm)
Note: If any “PT” value is set to zero, the controller
will stop and end the sequence at the point.
rPT.P = number of times the controller will repeat
the sequence (after the Pt9 has timed out, it will
return to Pt1 and repeat the sequence)
Running in manual set point mode.
Press “P” once, E-prog = no press, press “P” again,
run = yes, you can manually adjust the green temp
set point and oven is in “run hold” mode with no
timers. Use the “^-v” keys to change set point.
N1030T controllers only
From the main start up screen, press “P” to cycle
through time and run-hold options.
Press “P” once for timer display, twice for “T1” timer
set, third time is run option.
On the “run” screen select “yes” to run hold, “no” to
remove run command or “F” to enable the function
key.
Once you have enable the “F” key, push and hold
the F key for a 3 count, run command will applied
and controller will run for the amount of time set
on “T1”, when this timer reaches zero value, the run
command is removed from the controller.