Hot Shot HS-360 User Manual Download Page 5

Hot Shot  HS-360  Owner’s Manual R2.0  |  5

READY TO PROGRAM YOUR CONTROLLER NOW?

Novus 480D setting ramp and soak times, temps and events.

Novus 480D setting ramp and soak times, temps and events.
The oven comes with a factory installed USB port for programming the controller via a computer. Note: 

Disconnect oven from power source before plugging in USB.
Press and hold the “P” button till PTOL appears, the use the “P” button to scroll thru parameter group.

GROUP

PARAMETER

PSPO

starting temp (control temp starting pt)

Pt1

time 1 (set desired temp)

PSP1

temp 1 (set desired temp)

PE1

event 1 (off or A-1 for alarm)

Pt2

time 2 (desired temp)

PSP2

temp 2 (set desired temp)

PE2

event 2 (off or A-1 for alarm)

Pt3

time 3 (set desired time)

PSP3

temp 3 (set desired temp)

PE3

event 3 (off or A-1 for alarm)

Pt4

time 4 (set desired time)

PSP4

temp 4 (set desired temp)

PE4

event 4 (off or A-1 for alarm)

Pt5

time 5 (set desired time)

PSP5

temp 5 (set desired temp)

PE5

event 5 (off or A-1 for alarm)

Pt6

time 6 (set desired time)

PSP6

temp 6 (set desired temp)

PE6

event 6 (off or A-1 for alarm)

Pt7

time 7 (set desired time)

PSP7

temp 7 (set desired temp)

PE7

event 7 (off or A-1 for alarm)

GROUP

PARAMETER

Pt8

time 8 (set desired time)

PSP8

temp 8 (set desired temp)

PE8

event 8 (off or A-1 for alarm)

Pt9

time 9 (set desired time)

PSP9

temp 9 (set desired temp)

PE9

event 9 (off or A-1 for alarm)

Note: If any “PT” value is set to zero, the controller 

will stop and end the sequence at the point.
rPT.P = number of times the controller will repeat 

the sequence (after the Pt9 has timed out, it will 

return to Pt1 and repeat the sequence)
Running in manual set point mode.
Press “P” once, E-prog = no press, press “P” again, 

run = yes, you can manually adjust the green temp 

set point and oven is in “run hold” mode with no 

timers. Use the “^-v” keys to change set point.
N1030T controllers only
From the main start up screen, press “P” to cycle 

through time and run-hold options.
Press “P” once for timer display, twice for “T1” timer 

set, third time is run option.
On the “run” screen select “yes” to run hold, “no” to 

remove run command or “F” to enable the function 

key.
Once you have enable the “F” key, push and hold 

the F key for a 3 count, run command will applied 

and controller will run for the amount of time set 

on “T1”, when this timer reaches zero value, the run 

command is removed from the controller.