30
11) Press the Display Select Button 5 times to
advance to “A6”. This is the stage to set the
operation mode. If the Display Select Button
is pushed more than 5 times and the Display
Window shows a code other than “A6”,
continue to push the Display Select Button
until “A6” reappears.
12) Press the Flush Button once. The Display
Window will flash the current operation mode
(factory setting: “SFt.H”). The operation
mode can be set now. See Fig. 33.
13) Press the Display Select Button or Flush Button until the appropriate operation mode is
displayed depending on the unit installation condition. The Display Window continues to
flash.
SFt.H ---- With the Remote Controller installed.
SFt.P ---- With the Water Tank installed.
HANd --- Do not set (for the Remote Controller and Water Level Sensor application only).
POOL --- Do not set (for the Water Tank and Water Level Sensor application only).
Flashing
Fig. 33
Flashing
Fig. 34
Flashing
Flashing
Flashing