29
10. OPERATION MODE SETTING
CAUTION
Be sure to set the operation mode before operating the unit with the Remote
Controller or the Water Tank. Operating the unit without setting the operation mode
may lower the performance of the electrolytic water or spilling of acid electrolytic
water and/or alkaline electrolytic water.
1) Remove the Salt Water Hose from the Salt
Water Tank.
2) Turn the Power Switch on with the Door
open.
3) Press the Dispense Button on the Display
Panel.
4) Check that the Add Salt Water Lamp is on.
5) The Display Window on the Control Panel
will indicate the current operation time (h)
and the Operation Time Lamp is on. Press
the Set Button and keep holding down the
button.
6) Check that the Display Window is showing
”Nor”. “Nor” indicates that the unit is currently
in the Normal Mode. See Fig. 30.
7) Press the Display Select Button once while
holding down the Set Button.
8) Check that the Display Window is showing
“AdJ”. “AdJ” indicates that the unit is
currently in the Adjust Mode. See Fig. 31.
9) Release the Set Button.
10) Check that the Display Window is showing
”A1“. “A1” indicates that the unit is in Stage
1 of the Adjust Mode. There are 9 Stages in
the Adjust Mode. See Fig. 32.
Fig. 30
Lighting
Lighting
Display Select
Button
Fig. 31
Set Button
Lighting
Flush Button
Press once.
Flashing
Fig. 32
Lighting