26
* Put the Salt Water Hose through the Cap (Accessory) and push in the Salt Water Hose until
the Stopper hits the Cap. See Fig. 25. In case of using a larger tank, install the Salt Water
Hose so that the filter on the Salt Water Hose can reach the bottom of the tank.
Note: Install the piping so that the outlets are located above the Salt Water Filter on the end
of the Salt Water Hose. Due to the siphon phenomenon, salt water may leak from the
outlets if they are not high enough. See Fig. 26.
* Water supply inlet is 3/4” MPT. Connect the
unit with the Pressure Reducing Valve using
the Water Supply Hose (Accessory).
Note: Place the Gaskets between the Water
Supply Hose and unit water supply inlet
and the Pressure Reducing Valve and
t i gh t e n p r o p e r l y. I n c o m p l e t e
connection may cause water leakage.
See Fig. 23.
* Prepare a drain hose with a plastic shut-off valve if water needs to be removed from the unit
or water may freeze in the unit in cold areas. Remove the drain cap on the back of the unit
and attach the plastic joint, vinyl or PVC hose and plastic shut-off valve. Drain outlet is 3/4”
female pipe thread (FPT). See Fig. 24.
Fig. 23
Water Supply Hose
Pressure
Reducing Valve
Gasket
Gasket
Fig. 24
Rear Panel
Drain Cap
Joint (Plastic)
Vinyl or
PVC Hose
Shut-off Valve
(Plastic)
Fig. 25
Stopper
Install the piping so that the
outlets are located above
the Salt Water Filter on the
end of the Salt Water Hose.
Fig. 26