5
HOSHIZAKI EUROPE
B.V.
Depending on the temperature and air humidity at the installation site as well as the selected set point
setting, the moisture in the ambient air can condense on the surface of a refrigerating unit due to its design.
If several cooling or refrigeration units are set up side by side, this condensation effect becomes stronger,
and a lower air quantity can circulate between the cabinets. As a result, a minimum distance of
30 to 50 mm
must be kept between the cabinets depending on the temperature and air humidity.
These gaps must not be sealed either at the top or bottom, but can be covered by a stainless-steel panel
from the front for aesthetic purposes. The panel must be removable for cleaning within the gaps.
If it is not possible for air to circulate freely at the bottom, e.g. due to a base installation, then the gaps
cannot be sealed at the front.
4) Setting up Several Cabinets Side by Side
Summary of Contents for PREMIER 60
Page 39: ...39 HOSHIZAKI EUROPE B V PREMIER K 70 PREMIER M 70 PREMIER F 70 17 Dimensions...
Page 40: ...40 HOSHIZAKI EUROPE B V PREMIER KG 70...
Page 41: ...41 HOSHIZAKI EUROPE B V PREMIER K W80 PREMIER M W80 PREMIER F W80...
Page 42: ...42 HOSHIZAKI EUROPE B V PREMIER KG W80...
Page 43: ...43 HOSHIZAKI EUROPE B V PREMIER K 60 PREMIER M 60 PREMIER F 60...
Page 44: ...44 HOSHIZAKI EUROPE B V PREMIER KG 60...
Page 46: ...46 HOSHIZAKI EUROPE B V ELECTRICAL WIRING DIAGRAM FOR CABINET FREEZER MODELS...