24
HOSHIZAKI EUROPE
B.V.
PREMIER
K 60
PREMIER
KG 60
PREMIER
M 60
PREMIER
F 60
P.
CODE
DESCRIPTION
VALUE
VALUE
VALUE
VALUE
d4
enable defrost at power-on
0
0
0
0
d5
defrost dealy after power-on
0
0
0
0
d6
value displayed during defrost
2
2
2
2
d7
dripping time
3
3
3
3
d7b
dripping time for B
3
3
3
3
d8
defrost interval counting mode
0
0
0
0
d9
evaporation threshold for automatic defrost
interval counting
0
0
0
0
d11
enable defrost timeout alarm
0
0
0
0
d15
compressor on consecutive time for hot gas
defrost
0
0
0
0
d16
pre-dripping time for hot gas defrost
0
0
0
0
d18
adaptive defrost interval
999
999
999
999
d19
threshold for adaptive defrost (relative to optimal
evaporation temperature)
3
3
3
3
d20
compressor on consecutive time for defrost
999
999
999
999
d21
compressor on consecutive time for defrost after
power-on and overcooling
500
500
500
500
d22
evaporation threshold for adaptive defrost
interval counting (relative to optimal evaporation
temperature)
-2
-2
-2
-2
d25
enable air out probe for defrost during evaporator
probe alarm
0
0
0
0
d26
defrost interval during evaporator probe alarm
6
6
6
6
A0
select value for high/low temperature alarms
0
0
0
0
A1
threshold for low temperature alarm
10
10
10
10
A2
low temperature alarm type
0
0
0
0
A4
threshold for high temperature alarm
10
10
10
10
A5
high temperature alarm type
0
0
0
0
A6
high temperature alarm delay after power-on
120
120
120
120
A7
high/low temperature alarms delay
120
120
120
120
A8
high temperature alarm delay after defrost
120
120
120
120
A9
high temperature alarm delay after door closing
120
120
120
120
A10
power failure duration for alarm recording
240
240
240
240
A11
high/low temperature alarms reset differential
1
1
1
1
F0
evaporator fan mode during normal operation
1
1
1
1
F0b
evaporator fan mode during normal operation for
B
1
1
1
1
F1
threshold for evaporator fan operation
8
8
8
8
F2
evaporator fan mode during defrost and dripping
1
1
0
0
F2b
evaporator fan mode during defrost and dripping
1
1
1
0
F3
evaporator fan off maximum time for B
2
2
2
2
F3b
evaporator fan off maximum time for B
2
2
2
2
F4
evaporator fan off time during energy saving
30
30
30
30
Summary of Contents for PREMIER 60
Page 39: ...39 HOSHIZAKI EUROPE B V PREMIER K 70 PREMIER M 70 PREMIER F 70 17 Dimensions...
Page 40: ...40 HOSHIZAKI EUROPE B V PREMIER KG 70...
Page 41: ...41 HOSHIZAKI EUROPE B V PREMIER K W80 PREMIER M W80 PREMIER F W80...
Page 42: ...42 HOSHIZAKI EUROPE B V PREMIER KG W80...
Page 43: ...43 HOSHIZAKI EUROPE B V PREMIER K 60 PREMIER M 60 PREMIER F 60...
Page 44: ...44 HOSHIZAKI EUROPE B V PREMIER KG 60...
Page 46: ...46 HOSHIZAKI EUROPE B V ELECTRICAL WIRING DIAGRAM FOR CABINET FREEZER MODELS...