35
I. Rotate the alkaline chamber clockwise, 1/4 turn, and pull it out.
J. Insert a new alkaline chamber by rotating it counter-clockwise, 1/4 turn, until it clicks and stops. The arrow head
on the top collar should align with the arrow on the head.
K. Re-insert the water line into the “WATER IN” port on the back of the dispenser and re-open the main water line
valve.
L. Now flush the alkaline chamber by dispensing approximately 2 gallons of alkaline water using the alkaline touch
button. When the alkaline water comes out clear, the dispenser is ready.
M. At this point, before closing the side panel door, it is wise to check for leaks from the All-in-One filters HS-5441
and the alkaline chamber HS-5442. Make sure they are sealed correctly. Push the filter reset (”FR”) button at the
back of the dispenser for 10 seconds in order to reset the volumetric count of water consumption.
Replace the two HS-5441 Filters