34
3) Pour the sanitizing solution into the water tank.
4) Replace the insulation panel and the front panel in their correct positions.
Note: Make sure that the control switch is in the "WASH" position and the cleaning valve
is open.
5) Turn on the power supply to start the sanitizing process.
6) Turn off the power supply after 15 minutes.
7) Remove the front panel.
8) Remove the insulation panel. Remove cube guide B, then remove cube guide A.
Remove the overflow cap, overflow pipe, and water shield.
9) Remove the drain plug and drain the water tank. Replace the drain plug in its correct
position. Be careful not to cross thread it.
10) Replace the water shield, overflow pipe, overflow cap, cube guide A, cube guide B, and
insulation panel in their correct positions. Be careful not to cross thread the overflow
pipe.
11) Repeat steps 17 through 30 in "1. Cleaning Procedure" two times to rinse thoroughly.
12) Close the cleaning valve.
13) Move the control switch to the "ICE" position.
14) Replace the front panel in its correct position.
15) Clean the storage bin/dispenser unit liner using a neutral cleaner. Rinse thoroughly after
cleaning.
16) Turn on the power supply to start the automatic icemaking process.