![Hoshizaki KM-900MAF Service Manual Download Page 64](http://html1.mh-extra.com/html/hoshizaki/km-900maf/km-900maf_service-manual_2164736064.webp)
64
20) Turn on the power supply to fill the Water Tank with water.
21) Turn off the power supply after 3 minutes.
22) Remove the Front Panel, and fully open the Cleaning Valve.
23) Move the Control Switchto the “Wash” position.
24) Replace the Front Panel in its correct position.
25) Turn on the power supply to rise off the cleaning solution.
26) Turn off the power supply after 5 minutes.
27) Remove the Front Panel and Insulation Panel.
28) Drain the Water Tank by removing one end of the pump tuging. See Fig. 4.
After the tank has drained, replace the removed parts in their correct positions.
Note: Do not replace the Insulation Panel when you proceed to
“[b] SANITIZING PROCEDURE.’
29) Repeat the above steps 17) through 28) three more times to rinse thoroughly.
Note: If you do not sanitize the icemaker, go to step 9) in “[b] SANITIZING
PROCEDURE.”
[b] SANITIZING PROCEDURE - Following Cleaning Procedure
1) Dilute a 5.25% Sodium Hypochlorite solution (chlorine bleach) with water
(Add 1.5 fl. oz. of sanitizer to 3 gal. of water).
2) Remove the Insulation Panel, if it is in its normal position.
3) Pour the sanitizing solution into the Water Tank.
4) Replace the Insulation Panel and the Front Panel in their correct positions.
Note: Make sure that the Control Switch is in the “WASH” position and the
Cleaning Valve is open.
5) Turn on the power supply, and start the sanitizing process.
6) Turn off the power supply after 15 minutes.
7) Remove the Front Panel and if necessary, the Insulation Panel.
Summary of Contents for KM-900MAF
Page 9: ...9 5 CONDENSING UNIT URC 12F ...
Page 11: ...11 II GENERAL INFORMATION 1 CONSTRUCTION a KM 900MAF ...
Page 12: ...12 b KM 900MWF ...
Page 13: ...13 c KM 900MRF ...
Page 14: ...14 d KM 900MRF3 ...
Page 27: ...27 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 900MAF ...
Page 28: ...28 b KM 900MWF ...
Page 29: ...29 c KM 900MRF and KM 900MRF3 ...
Page 31: ...31 b KM 900MWF Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...
Page 32: ...32 c KM 900MRF Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...
Page 33: ...33 d KM 900MRF3 Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...