![Hoshizaki KM-900MAF Service Manual Download Page 59](http://html1.mh-extra.com/html/hoshizaki/km-900maf/km-900maf_service-manual_2164736059.webp)
59
8) Remove the closed end connectors from the Pump Motor leads.
9) Remove the two screws and the Pump Motor Bracket.
10) Remove the Pump Housing, and check the Impeller.
11) If the Impeller is defective, install a new Impeller.
12) Install the new motor or new parts, and replace the removed parts in the reverse
order of which they were removed.
13) Turn on the power supply, and check for leaks.
14) Replace the Base Cover.
15) Replace the Front Panel in its correct position.
15. REMOVAL AND REPLACEMENT OF SPRAY TUBES
1) Turn off the power supply.
2) Remove the Front Panel and the Insulation Panel.
3) Remove the Rubber Hoses from the Spray Tubes (Water Supply Pipe).
4) Release the Clamps, and disconnect the Rubber Hoses.
5) Remove the Spray Tubes by squeezing the side tabs.
6) Install the new Spray Tubes, and replace the removed parts in the reverse order of
which they were removed.
7) Replace the panels in their correct positions.
8) Turn on the power supply.
Summary of Contents for KM-900MAF
Page 9: ...9 5 CONDENSING UNIT URC 12F ...
Page 11: ...11 II GENERAL INFORMATION 1 CONSTRUCTION a KM 900MAF ...
Page 12: ...12 b KM 900MWF ...
Page 13: ...13 c KM 900MRF ...
Page 14: ...14 d KM 900MRF3 ...
Page 27: ...27 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 900MAF ...
Page 28: ...28 b KM 900MWF ...
Page 29: ...29 c KM 900MRF and KM 900MRF3 ...
Page 31: ...31 b KM 900MWF Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...
Page 32: ...32 c KM 900MRF Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...
Page 33: ...33 d KM 900MRF3 Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...