42
PROBLEM
POSSIBLE CAUSE
REMEDY
[4] Water
a) Water Solenoid
1. Diaphragm does not close.
1. Check for water leaks
continues to
Valve
with icemaker off.
be supplied in
b) Controller Board
1. Defective.
1. See “II.2.[e] CHECKING
freeze cycle.
CONTROLLER BOARD.”
[5] No water
a) Water Supply Line
1. Water pressure too low and
1. Check and get
comes from
water level in Water Tank
recommended pressure.
Spray Tubes.
too low.
Water Pump
b) Water Solenoid
1. Dirty mesh filter or orifice
1. Clean.
will not start, or Valve
and water level in Water
freeze cycle
Tank too low.
time is too c) Water System
1. Water leaks.
1. Check connections for
short.
water leaks, and replace.
2. Clogged.
2. Clean.
d) Pump Motor
1. Motor winding opened.
1. Replace.
2. Bearing worn out.
2. Replace.
3. Wiring to Pump Motor.
3. Check for loose
connection or open, and
replace.
4. Defective Capacitor.
4. Replace.
5. Defective or bound impeller. 5. Replace and clean.
6. Mechanical Seal worn out.
6. Check and replace.
e) Controller Board
1. Defective.
1. See “II.2. [e] CHECKING
CONTROLLER BOARD.”
[6] Fan Motor will
a) Fan Motor
1. Motor winding opened.
1. Replace.
not start, or is
2. Bearing worn out.
2. Replace.
not operating.
3. Wiring to Fan Motor.
3. Check for loose
connection or open, and
replace.
4. Defective Capacitor.
4. Replace
5. Fan blade bound.
5. Check and replace.
b) Controller Board
1. Defective.
1. See “II.2. [e] CHECKING
CONTROLLER BOARD.”
[7] All components a) Refrigerant
1. Undercharged.
1. Check for leaks and
run but no ice
recharge.
is produced.
2. Air or moisture trapped.
2. Replace Drier, and
recharge.
b) Compressor
1. Defective valve.
1. Replace.
c) Hot Gas Solenoid
1. Continues to open in freeze
1. Check and replace.
Valve
cycle.
d) Line Valve
1. Continues to close in
1. Check and replace
freeze cycle.
e) Water Supply Line
1. Condenser water pressure
1. Check and get
[Water-cooled model
too low or off and Pressure
recommended pressure.
only]
Control opens and closes
frequently.
Summary of Contents for KM-900MAF
Page 9: ...9 5 CONDENSING UNIT URC 12F ...
Page 11: ...11 II GENERAL INFORMATION 1 CONSTRUCTION a KM 900MAF ...
Page 12: ...12 b KM 900MWF ...
Page 13: ...13 c KM 900MRF ...
Page 14: ...14 d KM 900MRF3 ...
Page 27: ...27 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 900MAF ...
Page 28: ...28 b KM 900MWF ...
Page 29: ...29 c KM 900MRF and KM 900MRF3 ...
Page 31: ...31 b KM 900MWF Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...
Page 32: ...32 c KM 900MRF Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...
Page 33: ...33 d KM 900MRF3 Note Pressure Switch Cut out 412 PSIG Cut in 327 21 PSIG 21 0 ...