5
I. SPECIFICATIONS
1. KM-500MAH
Note: We reserve the right to make changes in specifications and design without prior notice.
AC SUPPLY VOLTAGE
115/60/1
AMPERAGE
13 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*499 (226)
468 (212)
428 (194)
Reference without *marks
80
475 (216)
427 (194)
389 (176)
90
468 (212)
*393 (178)
353 (160)
100
461 (209)
384 (174)
317 (144)
SHAPE OF ICE
Crescent Cube
ICE PRODUCTION PER CYCLE
9.5 lbs. ( 4.3 kg ) 480 pcs.
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1212 (7.4)
1164 (5.6)
WATER gal./24HR (gal./100 lbs.)
113 (28.8)
250 (50.1)
EXTERIOR DIMENSIONS (WxDxH)
22" x 27-3/8" x 30-5/6" (560 x 695 x 770 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 151 lbs. ( 69 kg ), Shipping 175 lbs. (80 kg)
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet 1/2" FPT
- DRAIN
Outlet 3/4" FPT
CUBE CONTROL SYSTEM
Float Switch
HARVESTING CONTROL SYSTEM
Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL
Timer Controlled. Overflow Pipe
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Proximity Switch with Delay
COMPRESSOR
Hermetic, Model AKA9455ZXA
CONDENSER
Air-cooled, Fin and tube type
EVAPORATOR
Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL
Thermostatic Expansion Valve
REFRIGERANT CHARGE
R-404A,
1 lb. 10 oz. ( 735 g )
DESIGN PRESSURE
High 467 PSIG, Low 230 PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION
Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch
ACCESSORIES -SUPPLIED
N/A
-REQUIRED
Ice Storage Bin
OPERATING CONDITIONS
VOLTAGE RANGE
104 - 127 V
AMBIENT TEMP.
45 -100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG
3/8" OD Pipe
Summary of Contents for KM-500MAH
Page 28: ...28 III TECHNICAL INFORMATION 1 WATER CIRCUIT AND REFRIGERANT CIRCUIT a KM 500MAH ...
Page 29: ...29 b KM 500MWH ...
Page 30: ...30 c KM 500MRH ...
Page 34: ...34 b KM 500MRH with auxiliary codes M 2 and after ...
Page 35: ...35 3 TIMING CHART ...
Page 36: ...36 ...