35
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact your
Hoshizaki Service Center.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S1 Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KM-231BAJ
OFF OFF OFF OFF ON ON OFF ON OFF ON
KM-301BAJ
OFF OFF OFF OFF ON ON ON OFF OFF ON
KM-301BWJ
OFF OFF OFF OFF ON ON ON OFF ON OFF
S2 Dip Switch (Do Not Adjust)
Dip Switch No.
1
2
3
4
5
6
KM-231BAJ
ON OFF OFF OFF OFF OFF
KM-301BAJ
ON OFF OFF OFF OFF OFF
KM-301BWJ
ON OFF OFF OFF OFF OFF
Do not adjust the S2 dip switch. These must be left in the factory default position, or the
appliance will not operate properly.
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Time (3 & 4)
Harvest Time (1 & 2)
Harvest Pump Time Duration (Harvest Assist) (7 & 8)
1
2
3
4
5
6
7
8
9
10
ON
S1 Dip Switch
1
2
3
4
5
ON
6
S2 Dip Switch
(do not adjust)
Harvest Completion Detection Control (4)
Pump-Out/Drain Selector (1)
Overfreeze Detection Control (5)
Slush Control (6)
Refill Counter (3)
Harvest Promotion Control (2)