61
8) Pour the cleaning solution into the water tank.
9) Move the control switch on the control box to the “WASH” position.
10) Refit the insulation panel and the front panel in their
correct positions.
11) Turn on the power supply, and start the washing process.
12) Turn off the power supply after 30 minutes.
13) Remove the front panel and the insulation panel.
14) Drain the water tank. (See step 6 above).
15) Refit the pump tubing in its correct position.
16) Move the control switch to the “ICE” position.
17) Refit the front panel in its correct position.
18) Turn on the power supply to fill the water tank with water.
19) Turn off the power supply after 3 minutes.
20) Remove the front panel.
21) Move the control switch to the “WASH” position.
22) Refit the front panel in its correct position.
23) Turn on the power supply to rinse off the cleaning solution.
24) Turn off the power supply after 5 minutes.
25) Remove the front panel.
26) Drain the water tank by removing one end of the pump tubing. See Fig. 5.
27) Refit the pump tubing in its correct position.
28) Repeat the above steps 16) through 27) three more times to rinse thoroughly.
Note: Sanitizing should always be completed after cleaning or alternatively as an
individual procedure if conditions exist to make it necessary.
If you do not sanitize the icemaker, go to step 11) in “2. Sanitizing Procedure.”
Summary of Contents for KM-280MAH-E
Page 8: ...8 II General Information A Dimensions 1 KM 280MAH E ...
Page 9: ...9 2 KM 500MAH E ...
Page 10: ...10 3 KM 630MAH E ...
Page 18: ...18 Control Products HOS 001A Board ...
Page 28: ...28 III Technical Information A Water Circuit and Refrigerant Circuit 1 KM 280MAH E ...
Page 29: ...29 2 KM 500MAH E KM 630MAH E ...