18
3) Drain Timer
The Drain Timer is factory-adjusted, and no adjustment is required.
SETTING
TIME
Dip Switch
Dip Switch
No. 3
No. 4
T1
T2
OFF
OFF
10 seconds
150 seconds
ON
OFF
10 seconds
180 seconds
OFF
ON
10 seconds
120 seconds
ON
ON
20 seconds
180 seconds
T1: Time to drain the Water Tank
T2: Time to restrain defrost completion
4) Drain Counter
CAUTION
Do not adjust the Drain Counter, or the Evaporator may freeze up.
The Drain Counter is factory-adjusted to drain the Water Tank every 10 cycles, and no
adjustment is required. However, where water quality is bad and the icemaker needs a
pump drain more often, the Drain Counter can be adjusted as shown in the table below:
SETTING
FREQUENCY
Dip Switch
Dip Switch
No. 5
No. 6
OFF
OFF
every cycle
ON
OFF
every 2 cycles
OFF
ON
every 5 cycles
ON
ON
every 10 cycles