50
B. Performance Data
Pressure data is recorded at 5 min. into freezing cycle.
APPROXIMATE
Ambient
Water Temp. (°F)
ICE PRODUCTION PER 24 HR.
Temp. (°F)
50
70
90
70
50(23)
47(21)
44(20)
80
49(22)
46(21)
43(20)
90
47(21)
45(20)
42(19)
lbs./day (kg/day)
100
44(20)
42(19)
39(18)
APPROXIMATE ELECTRIC
70
270
280
290
CONSUMPTION
80
280
285
295
90
285
295
305
watts
100
300
310
320
APPROXIMATE WATER
70
271(1.02)
75(0.28)
70(0.27)
CONSUMPTION PER 24 HR.
80
254(0.96)
72(0.27)
67(0.25)
90
242(0.92)
69(0.26)
65(0.25)
gal./day (m
3
/day)
100
227(0.86)
64(0.24)
61(0.23)
FREEZING CYCLE TIME
70
30.7
34.2
36.9
80
33.7
36.7
40.0
90
36.1
39.0
42.2
min.
100
39.5
43.3
46.1
HARVEST CYCLE TIME
70
9.7
10.2
10.4
80
9.3
9.6
9.6
90
9.0
9.2
9.2
min.
100
8.6
8.7
8.7
HEAD PRESSURE
70
110(0.75)
119(0.82)
126(0.87)
80
131(0.90)
141(0.97)
149(1.03)
90
152(1.05)
165(1.14)
171(1.18)
PSIG (MPa)
100
178(1.23)
189(1.30)
197(1.36)
SUCTION PRESSURE
70
17(0.12)
22(0.15)
28(0.19)
80
20(0.14)
23(0.16)
29(0.20)
90
20(0.14)
24(0.17)
29(0.20)
PSIG (MPa)
100
23(0.16)
26(0.18)
30(0.21)
TOTAL HEAT OF REJECTION 2600 BTU/h (AT 90°F / WT 70°F)