10
B. Sequence of Operation
1. Startup Cycle
When power supply is turned on, "on" appears on CB display and HGV energizes.
30 sec. later, harvest cycle starts.
• If the "RESET" button is pressed during 30-sec. startup cycle time, startup cycle ends
immediately and harvest cycle starts.
2. Harvest Cycle
See the timing chart on next page.
3. Freeze Cycle
See the timing chart on next page.
4. Shutdown
When BC is engaged (open) for more than 10 seconds, the icemaker shuts down after
harvest cycle.
When BC is disengaged (closed) for more than 80 seconds, icemaker restarts at startup
cycle.
If BC is engaged (open) while the water tank is opening after the power supply is turned
on (or after the "RESET" button is pressed), shutdown does not start: Shutdown occurs
10 seconds after actuator motor's internal position sensor indicates water tank is fully
open.
For details, see the timing chart on next page.
Legend:
BC
–bin control;
CB
–control board;
HGV
–hot gas valve