I. GENERAL INFORMATION
1. CONSTRUCTION
normal temperature range may affect cooling
performance.
For best operating results:
* The showcase should not be located next to ovens,
grills or other high heat producing equipment.
* The location should provide a firm foundation for
the equipment across its entire bottom surface. Any
unevenness or the insertion of packing resulting
in only partial contact could result in the case
becoming damaged or deformed causing a failure.
The showcase should always be level from side to
side and back to front.
Fig. 2
No good
Good
Nameplate
Joint Hose
Plug*
Circuit Breaker
Condenser
Air Filter
Slider
Louver
Sliding Glass Door
Food Mount
*Note: Always attach the two plugs to the drain holes located in
the showcase.
Fig. 1
II. INSTALLATION AND OPERATING
INSTRUCTIONS
1. CHECKS BEFORE INSTALLATION
* Visually inspect the exterior of the shipping container,
and any severe damage noted should be reported to
the carrier.
WARNING
Remove shipping carton, evaporator spacer,
tape(s) and packing. If packing material is left in
the showcase, it will not work properly.
IMPORTANT
Remove shipping tape holding the door.
* Remove the package containing accessories.
* See the nameplate on the rear of the showcase, and
check that your voltage supplied corresponds with
the voltage specified on the nameplate.
2. LOCATION
IMPORTANT
This showcase is not intended for outdoor
use. Normal operating ambient temperature
should be within 10°C to 30°C. Operation of the
showcase, for extended periods, outside of this
If the foundation is not firm enough, it may warp
and cause some space between its center and the
showcase bottom. In this case, provide a support to
keep the foundation level.
Fig. 3
Support
No good
Good
* Avoid a site where dripping is not allowed.
* Do not expose the showcase to direct sunlight or
higher temperatures to prevent damage to the plastic
housing.
* Allow at least 15 cm clearance between the
Condenser air outlet and the wall or other equipment
for proper air circulation. The rear and top of the
showcase should have enough space (at least 100
cm) for proper air circulation and smooth operation.
Fig. 4
Air Inlet
Air Outlet
100cm
100cm
15cm
Unit Height