50
VII. Technical Information
A. Electrical and Refrigerant Data
Model (includes drawer models)
AC Supply
Voltage
Amperes
Design
Pressure
(PSIG)
Refrigerant
(oz.)
HIGH LOW
134a
CRMR27 Undercounter, Worktop, and Prep Table
115/60/1
2.6
290
120
5.6
CRMF27 Undercounter and Worktop
115/60/1
3.4
310
120
5.0
CRMR36 Undercounter, Worktop, Prep Table, and Mega
Top
115/60/1
2.9
290
120
5.6
CRMR48 Undercounter and Worktop
115/60/1
2.6
240
120
6.5
CRMR48 Prep Table and Mega Top
115/60/1
2.6
290
120
6.5
CRMF48 Undercounter and Worktop F-7 and Earlier
115/60/1
6
360
140
9.2
CRMF48 Undercounter and Worktop G05 and Later
4.7
360
140
7
CRMR60 Undercounter and Worktop
115/60/1
4.2
290
120
8
CRMR60 Prep Table and Mega Top F-7 and Earlier
115/60/1
6
360
140
10.3
CRMR60 Prep Table and Mega Top F-8 and Later and
Models Converted with SP-5227 Kit
9.5
CRMF60 Undercounter and Worktop F-7 and Earlier
115/60/1
6
360
140
10.6
CRMF60 Undercounter and Worktop G-5 and Later
9.5
360
140
9.5
CRMR72 Undercounter and Worktop
115/60/1
4.2
290
120
8
CRMR72 Prep Table and Mega Top F-7 and Earlier
115/60/1
6
360
140
12
CRMR72 Prep Table and Mega Top F-8 and Later and
Models Converted with SP-5227 Kit
10.4
See the nameplate for electrical and refrigeration specifications. The nameplate is located
inside the cabinet.
We reserve the right to make changes in specifications and design without prior notice.