![Hoshizaki C-80BAJ Service Manual Download Page 19](http://html1.mh-extra.com/html/hoshizaki/c-80baj/c-80baj_service-manual_2164933019.webp)
19
Refill
1. Float Switch
See "II.D. Float Switch Check
and Cleaning."
a) Dirty/sticking.
b) Defective.
2. Inlet Water Valve
a) Screen or orifice clogged.
b) Defective.
3. Water Supply
a) Water supply off or improper water pressure (7 to 113 PSIG).
b) External water filters clogged.
4. Water Control Relay
a) Defective.
5. Time Delay Relay
a) Defective.
Shutdown
1. Bin Control Thermostat Assembly
(with integrated heater)
a) Open with bin filled with ice.
b) Out of position.
c) Out of adjustment. See "II.C. Bin Control Check."
d) Bad contacts.
e) Bad thermostat heater.