Maestro RC manual mode
CONFIGURATION
Machine
:
Maestro RC
Additional hopper
:
no
cent.hopper SOD
:
no
Hydraulic valve block
:
Track
coult.press.set
:
Hyd Auto
max.coult.pres
:
215
Metering unit
1:
without
Metering unit
2:
without
fertiliser monitoring
:
no
Detail view
:
no
Maestro RC configuration
For the Maestro RC solo with 3-point attach-
ment the maximum coulter pressure is limited
to 215 kg. The limit value can be adjusted under
max. coulter pressure
.
Automatic mode
AutoForce
No
calculation of residual quantity
1
2
3
AutoForce
screen - Automatic mode
Softkey for switching the automatic
mode on and off.
Softkey for changing the coulter pres-
sure target value.
1. The diagram shows the layout of the sections.
The standard sections are shown in black,
the sections in the tracks in grey.
2. In the centre area of the display target values
for the force between the depth guide wheels
and the soil for standard sections (black) and
sections in the tracks (grey) can be entered.
¾
For systems with more than one section, set
the target value in the tracks higher than in
the standard sections.
Target value range for automatic mode:
50 - 100 kg.
NOTE
The target values must be determined in the
field.
¾
Check the quality of sowing and placement
depth in the field several times and daily in
case of different soil conditions.
¾
Correct the values for the coulter pressure
as required.