Display / error
Meaning
Possible causes
Solution options
Sensor failure
The system continues working as long as one sensor
still functions.
Check if the use of
AutoForce
is still practical.
Short-circuit (measured value > 25 mA); the input to the
job computer was disabled.
Turn the machine off and on again. The job computer is
reset if the fault was rectified.
Wiring between sensor and slave computer is defective.
Replace the affected component.
Sensor defective.
Replace the sensor.
Deactivate the failed sensors in the parameter screen.
Switch to manual mode.
Check the coulter pressure
Check the selection of the coulter pressure valve.
Open
Diagnostics
and check the sensor values.
Switching on the fertiliser and demand fan.
Adjust the % values in diagnostics.
The hydraulic pressure rises when increasing the PWM
signal; observe the pressure gauge on the fertiliser
hopper.
Only values in the range of 25-55 % cause a change of
the hydraulic pressure.
Uneven placement depth
Placement depth differs from row to row.
Cam wear differs from row to row.
Replace cams.
Sensor calibration values not okay.
Teach sensor.
Placement depth in row varies.
Speed too high.
Reduce the speed.
Sensor calibration values not okay.
Teach sensor.
22
23