Horotec VIBRATO MSA 19.709 Operating Manual Download Page 23

23   

   

   

Abbreviations   and   meanings   of   the   cleaning   movements   :   

   

Abbreviation

 

Movement

 

Description

 

ST

 

Stop

 

No   turning

 

ST

 

Slow   turning

 

t/2   

to   

left   side,   then   right

 

FT

 

Fast   turning

 

t/2   left   side,   then   right

 

SA

 

Slow   alternating

 

n   turns   left,   then   n   turns   right

 

FA

 

Fast   alternating

 

n   turns   left,   then   n   turns   right

 

SO

 

Slow   oscillating

 

n   turns   left,   then   0,7n   turns   

right

 

FO

 

Fast   oscillating

 

n   turns   left,   then   0,7   n   turns   

right

 

SX

 

Slow   extra   (osc+   up/down)

 

n   turns   left,   then   0,7   n   turns   

right   +   u

p   and   down

 

FX

 

Fast   extra   (osc+   up/down

 

n   turns   left,   then   0,7   n   turns   

right   +   

p   and   down

 

VB

 

Vibrasonic   

(

optional

)

 

n   turns   left,   then   0,7   n   turns   
right   (fast   acceleration   –   

vibrasonic   movement)

 

   

   

Now,   one   can   globally   set   the   rotation   speed   for   every   single   movement.   For   oscillating   or   changing   
movements,   the   optional   software   also   offers   the   setting   for   the   number   of   rotations.   Otherwise,   the   
factory   values   will   be   displayed.   

   
   

   

"Heating"   :   

The   temperatures   for   "WA"   warm   air   and   “HA”   hot   air   can   be   set.   Please   note   that   the   heating   

due   to   the   air   tube   made   of   stainless   steel   has   certain   inertia.   By   pressing   the   [START/stop]   button,   one   can   
test   the   heating   and   directly   read   the   temperature   of   the   air   at   the   sensor.   
Please   make   a   test   without   any   pieces,   to   approach   the   ideal   heating   temperature   and   time   to   avoid   
overheating   of   the   pieces   to   dry.   
   
   
   

"Beeper":   

activate   or   turn   off   the   confirmation   beep   emitted   by   pressing   the   ENC.   

   

   

   

   

Summary of Contents for VIBRATO MSA 19.709

Page 1: ......

Page 2: ...ing this option the VB movement can be selected and customized in the settings During this oscillating motion vibrating movement it is possible to constrain the rotation angle to 36 degrees MSA19 710...

Page 3: ...age 5 5 Safety instructions Page 6 6 Technical data Page 7 7 Starting Pages 8 9 8 Operation Page 10 9 Equipment Pages 11 13 10 Creating cleaning programs Pages 14 18 11 Performing cleaning programs Pa...

Page 4: ...cm for organic solvents The amplitude of the depression to be supplied to reach the cavitation threshold depends on several parameters the higher the viscosity of the media therefore the internal coh...

Page 5: ...economical an alternative to solvents biodegradable detergents reduced cleaning time accurate effective and easy 4 EC declaration of conformity This device complies with European standards CE accordi...

Page 6: ...e of the unit by any other person is not possible Make sure that the machine operates only in a well ventilated room or connected to an external exhaust Take care when loading the machine not to damag...

Page 7: ...packing 102 kg Dimensions 480 x 480 x 760 mm Country of origin Germany Specific technical shipping information Extracted air Internal 80 mm Suction force 26 qm h free movement Standard content of del...

Page 8: ...ered in winter at very low temperatures the formation of condensation can damage the electronics In this case and before use leave the device at room temperature for 24 hours to avoid any risk of dama...

Page 9: ...achine to the power supply 2 Switch on the machine by pressing the On Off switch to 1 The unit performs a first self test and starts the initialization This means that all axes will go to the referenc...

Page 10: ...r looks like two brackets around the value to be modified Value To change a value press briefly on the ENC which changes the brackets around the value Value Turning the ENC can now change the value it...

Page 11: ...can rotate freely The wave breakers placed in the tanks prevent rotation of the fluid 2 Fill the tanks up to the mark with the desired cleaning fluid Beware of the instructions for use concerned fluid...

Page 12: ...he position of the individual tank on the turntable and starts with the ultrasonic bath B1 counter clockwise This allows the identification of the tank and its position on the turntable which cannot b...

Page 13: ...ing CAUTION If for both Cleaning cycles and Age in days a maximum value is defined the consumption bar displays the value that comes first to the limit or the one that is closest If during cleaning th...

Page 14: ...very position All the steps can be programmed in any order and are not related to the sequence of the baths in the machine Similarly individual tanks can be repeatedly used with different cleaning mov...

Page 15: ...determined on the basis of different cleaning times in each bath spinning and drying times as well as the duration of the movements As soon as a cleaning program has been completely executed the machi...

Page 16: ...tep select the field New step and confirm with the ENC Left you see the statement on the menu It is also possible to insert a new step at any point of an existing program with the START STOP button Af...

Page 17: ...is will be explained later in this manual The following movements are available LD SD LW SW LO SO LX SX VB optional 03 00 Setting the duration of the bath This means how long the basket in movement li...

Page 18: ...he PTC heating element Please make a test run without any pieces after each temperature setting When all the cleaning cycle steps are performed one can access to the summary of the program by moving t...

Page 19: ...sically the machine starts with the last executed or changed cleaning program To select a different program turn the ENC until the name of the program is highlighted or black and confirm the selection...

Page 20: ...s ALWAYS by pressing the Start Stop button to prevent accidental starts during the manipulation with the ENC Interrupt the cleaning program If the Start Stop button is pressed during an active cleanin...

Page 21: ...om the fluid and the spinning cycle begins if programmed before the next step starts If the cleaning basket had no contact with the fluid the spinning movement is skipped and the step begins immediate...

Page 22: ...basket for each bath and the degrees of rotation of the simple movements if enabled To try this option press the Start Stop button Here all settings can be made For example the rotational speed of th...

Page 23: ...ns left then 0 7 n turns right fast acceleration vibrasonic movement Now one can globally set the rotation speed for every single movement For oscillating or changing movements the optional software a...

Page 24: ...s the currently unlocked functions Furthermore the other functions can be unlocked To unlock an optional function please contact us to get the code The machine generates a new request code REQ at ever...

Page 25: ...as to be controlled and if necessary applied some grease To do this we recommend you the spindle grease reference L1 ZBH003 applied with a bristle brush through the slots in the front panel Check air...

Reviews: