93-0061-00 Rev. A
11
Adflo
®
Turbo Unit
Fault
Probable Cause
Possible Solutions
Battery pack’s charge lasts less
than 6 hours
The motor runs “faster than
normal”
The motor runs “slower than
normal”
1) Inadequate charging
2) HE filter is loaded with
particles, making the motor run
harder
1) The HE filter is loaded with
particles
2) Recent user change from HE
filter and OV/SD/CL/HC
cartridge to just the HE filter
1) Recent user addition of
OV/SD/CL/HC cartridge
1) Fully discharge & charge the
battery pack 3 times, as per
Section 2.1
2) Replace the HE filter &
prefilter, and examine the spark
arrestor
1) Replace the HE filter &
prefilter, and examine the spark
arrestor
2) Let the unit run for 2 minutes so
it can automatically adjust to
the new filter media or changes
to the filter configuration
1) Let the unit run for 2 minutes so
it can automatically adjust to
the new filter configuration
If further assistance is required, contact your Hornell distributor or the
Hornell technical support staff (see Chapter 4).