71
EN
Troubleshooting
Problem
Possible cause
Solution
Motor does not run
No power supply
Make sure the voltage meets the
requirements stated in the technical
data
Defective cable
Deliver the machine to a recognised
workshop for repairing
Motor is growling,
running but not
starting
Gear ring is blocked
Clean the ring gear
Defective condenser
Deliver the machine to a recognised
workshop for repairing
Mixer gets blocked
by small loads,
switches off auto-
matically
The extension cable does not
meet the requirements
Required cross section area for exten-
sion cables:
1.5 mm
2
- up to 25 m
2.5 mm
2
- longer cables
Contact pressure on
the hand wheel is too
loose
The pressure spring is not
sufficiently tight
Tighten the screw (page IX)
Drum is not rotating
after starting
Defective V-Belt or mismatch-
ing voltage
Make sure the voltage meets the
requirements stated in the techni-
cal data Deliver the machine to a
recognised workshop for changing
the V-Belt