HORN 027170211 Operating Manual Download Page 7

44 1538 101-B     

Manual flow meter FMOGne 

2.4.3

2.4.3

2.4.3

2.4.3

 

Battery 

Lithium battery (Type CR ½ AA, 3.6V, 1200 mAh) with a minimum operating life of 
approx. 10 years given a 1,000,000 litre flow rate during this period.  

The battery can be replaced once the housing is opened. Cumulative and calibration 
values are not affected by replacement. 

2.4.4

2.4.4

2.4.4

2.4.4

 

Recording of measurement values 

Logging the measurement chamber double-pulse signal. 

Fault-redundant storage and read-out of measurement unit and calibrating factor. 

3.

 

Operating manual 

3.1

 

Delivery state 

On delivery the meter is provided with the factory “litre” measurement unit and the 
“1,000” calibrating factor. Pre-tested meters have a calibrating factor already factory-
adjusted. Alternatively this adjustment can be undertaken at a later date. The meter 
as it is can meter deliveries. 

3.2

 

Basic state, flow measurement 

In the basic state the LC display indicates the metered volume since the last reset. The 
display has three digits before the decimal point and two after; 0.01 litre is the 
minimum digital step. The “litre” measurement unit (optional US-Gal, UK-Gal) is shown 
on the lower line. 

3.3

 

Reset – “Reset” key 

On pressing the “Reset” key, the programme status is shown for as long as the key 
remains pressed. On releasing the key, all the segments are tested one after the other 
followed by flow meter resetting. Should pulse signals proceed (volume flow) during 
the above, then the display test is interrupted and changed to the basic state. 

3.4

 

Totaliser – Key “Total” 

On pressing the “Total” key, the totaliser status is shown for as long as the key 
remains pressed. The display is rounded in litres (optional US-Gal, UK-Gal). Should 
pulse signals proceed (volume flow) during the display, then the totaliser status 
display is interrupted and changed to the basic state. 

3.5

 

Calibrating factor display – Keys “Total” + “Reset” 

When the “Reset” key is pressed in addition to the pressed “Total” key (totaliser 
status display), the set calibrating factor is displayed for as long as the two keys are 
pressed. The calibrating factor can be between 0.500 and 1.500.  

 

Should pulse signals proceed (volumetric flow) during the display, then the calibrating 
factor display is interrupted and changed to the basic state. 

Summary of Contents for 027170211

Page 1: ...Translation of the original operating manual Operating manual Manual flow meter FMOGne Item No 027170211 027170221...

Page 2: ...insufficient knowledge of the operating manual Copyright HORN GmbH Co KG All rights reserved Text graphics and layout copyright protected Reproduction and copying including in part only permitted wit...

Page 3: ...ing Fault monitoring Fault monitoring Fault monitoring 8 8 8 8 4 1 Battery symbol display in the basic state 8 4 2 Display of five dashes 8 5 5 5 5 Meter programming Meter programming Meter programmin...

Page 4: ...e liquids listed and the purpose described Using the machine for any other purpose would constitute inappropriate use The manufacturer is not responsible for any loss arising as a result of this the r...

Page 5: ...may work on devices for flammable and or water endangering substances During such works appropriate tools are to be used avoid sparking Before any kind of work on the device all fuel lines are to be c...

Page 6: ...tion The standard scope of supply includes the rubber protection ring for the meter and the full hose nozzle in addition to the meter with handle 2 2 Product versions Item no Description Description 0...

Page 7: ...nt and two after 0 01 litre is the minimum digital step The litre measurement unit optional US Gal UK Gal is shown on the lower line 3 3 Reset Reset key On pressing the Reset key the programme status...

Page 8: ...it litre US Gal UK Gal and the calibrating factor 0 500 1 500 can be set and stored in a fault redundant manner Before a new calibrating factor can be established a delivery must be made into a satisf...

Page 9: ...e Mode key and the set calibrating factor is taken on 5 5 Resetting all settings initialisation The effect of pressing and holding the Total and Reset keys at the same time when setting the measuremen...

Page 10: ...ccording of this operating manual However if you should require further assistance please contact the Horn service department 8 Disposal The device is to be emptied completely and the liquids properly...

Page 11: ...44 1538 101 B Manual flow meter FMOGne 11 9 Declaration of conformity...

Page 12: ...12 44 1538 101 B Manual flow meter FMOGne HORN GmbH Co KG Munketoft 42 24937 Flensburg Germany T 49 461 8696 0 F 49 461 8696 66 www tecalemit de info tecalemit de...

Reviews: