background image

8

9

Operating instruction for electric fence controller hotSHOCK A50
with GPS SECURITY and SMS CONTROL

in connection with safety hints SECURA ANIMAL or SECURA SECURITY  
(www.horizont.com)

Installation and connection:

  

The controller can be mounted alternatively onto a wall or a solid post. The earth stake must 
be inserted into the ground as far as possible at a moisty place and must be connected to 
the earth terminal 

 ) of the controller by means of a noncorrosive wire. 

Connect the fence connecting lead to the fence terminal ( 

 or   ) - fig. 3

The controller is water protected only when being installed acc. the instructions. Prodect 
from bright sunshine. Do not operate the energizer when laying on the ground.

Operation 

(see fi g. 2)

Connect the controller to a 12V wet battery 

( red + / black - )

, ensure that the terminals are 

absolutely clean and the polarity is correct.  
Use only rechargeable 12V- lead-acid batteries, during charging lead-acid batteries must be 
placed in a well-ventilated area.

Press the switch 

(1)

The battery indicator light 

(2)  „accu-test“ is 

permanent 

green      = 

battery 

is 

fully 

charged 

                

no light or flashing green     = battery must be charged

After a few seconds a slight tic-tac can be heard. The control lamp 

(3)

  fl ashes with the 

pulses. In case of wrong polarity  the controller will not operate. If the control lamp 

(3)

 fl ashes 

with the the pulses energizer operates properly. If this lamp is not or steady illuminated the 
energizer is faulty.

fi g. 2:

The energizer has two fence terminals 

(Z1) = max output 

 (Z2) = reduced output

Both outlets can operate separate fences at the same time. A short in the  Z2 fence has 
no strong infl uence on Z1 but a short or a deviation in Z1 means a further reduction of Z2.

Grounding:

  

For a faultless operation and to obtain best possible output a good grounding  is very im-
portant. There fore the grounding must be made at a rather moisty and overgrown place. 
An 1 m earth stake ( e.g. 12mm ø ) shall be used. With long fences and on dry soil a ground 
return wire with intermediate groundings (every 50 m) is necessary. (fi g. 4)

Service:  

Servicing is only to be made by qualifi ed service personell. 
Only by the manufacturer commanded replacement parts must be used.

en

Operating instructions for GPS SECURITY and SMS CONTROL: 

Installation and connection:

The additional device GPS SECURITY and SMS CONTROL device are built in operable in the electric fencer. Please 
let your SIM card unlock with the help of the enclosed documents.

Operation of the additional device GPS SECURITY and SMS CONTROL:

Please connect the electric fencer with the 12 V battery The additional module is available after 2 minutes approxi-
mately.

Status check by calling the additional device and status advise for status information via SMS:

Please call to the additional device from a cell phone. The call will be interrupted after 2 call signs.
You will get an SMS from the additional device with following information, which you will get with each status update:
 
http://maps.google.com/maps?f=q&hl=en&q=………  
You can enter the coordinates by yourself in google-maps and query the location. The link can be opened immediately 
from your mobile phone (Smartphone) in google-maps. The location of the electric fencer will be shown. 

loc: 51.286368,8.857165

 ..........Location coordinates of the electric fencer

&speed: 0.00

 ............................Current speed of additional device over ground

01/01/13 11:55

 .........................Date and time of the last allocated location

F:4,32V

 ....................................current voltage of backup battery of the additional 

module

M:12,0V

 ...................................Current voltage of the 12 V main power source*

Signal: F oder L

 .........................F means that the GPS signal suffi ce for the esta-

blishment. L means that the GPS signal is insuffi ci-
ent for the establishment.

Imei:012896000578432

 ............Device  identifi cation number

* Voltages above 12 volts are shown as 12V (and not 
as 13,6 volts for example). The voltage value can 
fl uctuate at +/- 0,4 volts around the shown value.

Alert message:

You will get following alert messages from the device if the voltage limits are rea-
ched or the location of the electric fencer has changed:

Signal:F low voltage

 .................The voltage of the 12 V main power source has fallen to 11,4 Volt or less 

Signal:F Low batt

 ......................The voltage of the internal backup battery ensures operation of the additional device 

for a few more minutes. During this time, the additional device can’t communicate with 
you, until the electric fencer is again  connected to the power source.

Signal:F moved

 .........................The electric fencer has been disconnected from it`s referred location.

Location and 

movement functions:

Send a SMS to the additional device with following content:           

 

move300

 

The given answer of the additional device will be:  

 

move ok

The additional device will memorize the location. If the fencer is moved more than 300 m from the allocated location, 
the mobile phone which was sending “move300”, will get a SMS again.
Content of the SMS will be:  

 

Signal:F moved

Send a SMS to the additional device with following content:               

 

nomove 

The given answer of the additional device will be:                             

 

nomove ok

The additional device will not memorize the location. Relocation will not be reported in the future.

Advise: Before you register your fencer in a new location you have to cancel the previous location  with nomove.

http://maps.google.com/

mapsßf=q&hl=en&q=loc

:51.286368,8.857165&sp

eed: 0.00 01/01/13 11:55 

F:4,32V Signal:F Imei: 

012896000578432

additional device:

Summary of Contents for hotSHOCK A50

Page 1: ...1 00 Telefax 49 0 56 31 5 65 1 20 agrar horizont com www horizont com 85300B 07 13 hotSHOCK A50 Type 10613GPSD 12V DC BETRIEBSANLEITUNG Elektrozaungerät de OPERATING INSTRUCTION Electric Fencer en MODE D EMPLOI Électrificateur de Clôture fr GPS SECURITY und SMS CONTROL mit Zusatzmodule with additional device avec module supplémentaire ...

Page 2: ...90 84719 88148 94581 97683 90429 60183 60219 84741 89474 94581 90005 89976 90739 98444B 10613GPS 98271 schwarz 97999 rot Fig 3 Fig 4 97999 rot Montage und Anschluss Fig 1 Ersatzteile Spare parts Pièces détachées Fig 2 Ersatzteile Spare parts Pièces détachées ...

Page 3: ...URITY und SMS CONTROL ist funktionsbereit im Weidezaungerät verbaut und ange schlossen Die SIM Karte ist in dem Zusatzmodul fest verbaut Bitte leiten Sie die Freischaltung Ihrer SIM Karte wie folgt ein E Mail an sim freischalten t online de Betreff SIM Ihre Rufnummer Gerät Ihre Telekartennummer Name Vorname Straße Plz Wohnort Geburtsdatum Telefon E Mail Die Freischaltung erfolgt innerhalb von 24 S...

Page 4: ...elefon sowie mit bis zu vier weiteren Mobiltelefonen Hierzu müssen sie ihr Mobiltelefon zunächst als Master anmelden Schicken Sie eine SMS an das Zusatzmodul mit folgenden Inhalt admin IHRE Mobiltelefonnummer Beispiel admin 00491718952860 admin Befehl Leerzeichen 0049 Landeskennung 1718952860 IHRE Mobiltelefonnummer Hinweis Um Kommunikationsproblemen bei der späteren Datenübertragung vorzubeugen g...

Page 5: ...ry The additional module is available after 2 minutes approxi mately Status check by calling the additional device and status advise for status information via SMS Please call to the additional device from a cell phone The call will be interrupted after 2 call signs You will get an SMS from the additional device with following information which you will get with each status update http maps google...

Page 6: ... stable mobile reception and a good cover with GPS satellites Depending on the mobile reception and the additional device it can be a time delay during SMS sending Also can accrue time delays because of the communication between different network operators The quantity of the satellites can vary because of bad meteorological conditions fencer location under roofs or other shields The establishment...

Page 7: ...ux satellites GPS pour éviter les temps de retard lors de la localisation du site ou imprécision lors de la connexion Mode d emploi pour GPS et GSM Contrôle de sécurité Installation et raccordement Le système GPS Sécurité et Dispositif de contrôle SMS sont construits en pouvant fonctionner dans l électrificateur Operation of the additional device GPS SECURITY and SMS CONTROL Connectez l électrific...

Page 8: ...V 5500V Akku Nachladung nach ca Stunden Ah 0 54 A Technische Daten hotSHOCK A50 GPS Type 10613GPSD max 80 km max 80 km 3 CEE max Zaunlänge TECHNISCHE ÄNDERUNGEN VORBEHALTEN SUBJECT TO TECHNICAL ALTERATIONS SOUS RÉSERVE DE CHANGEMENTS TECHNIQUES Notizen Notes Note ...

Page 9: ...16 ...

Reviews: