311
SmartStacker User's Manual
If an Error Code Is Displayed on SmartStacker
Code
Description and Causes
Solutions
5380
Current leakage protection
(Inverter display: E.GF)
A ground fault has occurred in the power supply
circuit of the motor, and the inverter stopped the
output.
If this error occurs frequently, call your local
dealer.
5381
Output phase failure protection
(Inverter display: E.LF)
A phase failure has occurred in one of the three
output phases (U, V and W) from the inverter. The
output from the inverter has been stopped.
5390
Parameter problem
(Inverter display: E.PE)
A parameter saved for the inverter is bad.
5399
No error code for inverter
(Inverter display: N/A)
An error which does not correspond to any of the
errors 5300 through 5398 has occurred on the
A460 inverter for output shift sliding motor.
A590 Inverter for Register Section Transport Motor: 5600-5699
5600
Inverter No Response
(Inverter Display: N/A)
The communication connection between
the inverter, the Reinforced Insulation
Communication Board P110413 (QPW-943) and
the Control Board P109512 (QPM-290) for the
Merge Conveyor has not been established.
Close all the covers and make sure the
Emergency Stop button is released.
5601
Inverter Communication Error
(Inverter Display: N/A)
The Control Board P109512 (QPM-290) for the
Merge Conveyor P109512 (QPM-290) received
NAK several times from the inverter.
If this error occurs frequently, call your local
dealer.
5610
Inverter Alarm
Overcurrent During Acceleration
(Inverter Display: E.OC1)
During acceleration, the output current of the
inverter became double the rated current.
Summary of Contents for SmartStacker
Page 106: ...This page is intentionally left blank ...
Page 110: ...110 SmartStacker User s Manual Daily Safety Check Lift the cover pressing the hooks Hooks ...
Page 146: ...This page is intentionally left blank ...
Page 170: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 207: ...6 This chapter explains some possible problems and suggests some solutions 6 Troubleshooting ...
Page 367: ...367 SmartStacker User s Manual If a Jam Occurs B2 Stacker Option 10606650901C1 Feeder Option ...
Page 368: ...This page is intentionally left blank ...
Page 376: ...376 SmartStacker User s Manual SmartStacker Merge Conveyor Merge Stacker B2 Stacker Optional ...
Page 379: ...379 SmartStacker User s Manual SmartStacker B2 Stacker Optional Vacuum Belt ...
Page 381: ...381 SmartStacker User s Manual SmartStacker Merge Conveyor ...
Page 390: ...This page is intentionally left blank ...
Page 391: ...6 8 This chapter lists the specifications for this machine 8 Appendix ...
Page 411: ...This page is intentionally left blank ...
Page 412: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...