265
SmartStacker User's Manual
If an Error Code Is Displayed on SmartStacker
Code
Description and Causes
Solutions
3741
Servo amplifier communication failure
(Amplifier display: N/A)
The communication is not stable. A
communications data error occurred.
Check if Q230 breaker is not tripped.
3742
Drive power undervoltage
(Amplifier display: N/A)
The voltage of the power supplied to the servo
amplifier is insufficient.
If this error occurs frequently, call your local
dealer.
3750
No error codes
(Amplifier display: N/A)
An unexpected error occurs on the servo
amplifier.
(An error which does not correspond to any of the
errors 3701 through 3749 has occurred.)
If this error occurs frequently, call your local
dealer.
A240 Inverter for 2nd Process Unit Transport Motor: 3800-3899
3800
Inverter no response
(Inverter display: N/A)
The communication connection between the
inverter, the short circuit board P109111 (QPW-
936), the reinforced insulation communication
board P110413 (QPW-943), and the control
board P109512 (QPM-290) for the 2nd regist unit
has not been established.
Close all the covers and make sure the
Emergency Stop button is released.
3801
Inverter communication error
(Inverter display: N/A)
The control board P109512 (QPM-290) for the
2nd regist unit received NAK several times from
the inverter.
If this error occurs frequently, call your local
dealer.
3810
Inverter alarm
Overcurrent during acceleration
(Inverter display: E.OC1)
During acceleration, the output current of the
inverter became double the rated current.
3811
Inverter alarm
Overcurrent during constant speed
(Inverter display: E.OC2)
During constant-speed operation, the output
current of the inverter became double the rated
current.
Summary of Contents for SmartStacker
Page 106: ...This page is intentionally left blank ...
Page 110: ...110 SmartStacker User s Manual Daily Safety Check Lift the cover pressing the hooks Hooks ...
Page 146: ...This page is intentionally left blank ...
Page 170: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 207: ...6 This chapter explains some possible problems and suggests some solutions 6 Troubleshooting ...
Page 367: ...367 SmartStacker User s Manual If a Jam Occurs B2 Stacker Option 10606650901C1 Feeder Option ...
Page 368: ...This page is intentionally left blank ...
Page 376: ...376 SmartStacker User s Manual SmartStacker Merge Conveyor Merge Stacker B2 Stacker Optional ...
Page 379: ...379 SmartStacker User s Manual SmartStacker B2 Stacker Optional Vacuum Belt ...
Page 381: ...381 SmartStacker User s Manual SmartStacker Merge Conveyor ...
Page 390: ...This page is intentionally left blank ...
Page 391: ...6 8 This chapter lists the specifications for this machine 8 Appendix ...
Page 411: ...This page is intentionally left blank ...
Page 412: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...