233
SmartStacker User's Manual
If an Error Code Is Displayed on SmartStacker
Code
Description and Causes
Solutions
1430
Stack table full error
While the machine is running, the height of the
stack table became 5 mm / 0.20” or lower.
Decrease the stack amount.
1440
Separation air blower motor M411 failure
The error signal from the M411 separation air
blower motor is received by the control board.
If this error occurs frequently, call your local
dealer.
1441
Vacuum air blower motor M421 failure
The error signal from the M421 vacuum motor 1
is received by the control board.
1442
Vacuum air blower motor M422 failure
The error signal from the M422 vacuum motor 2
is received by the control board.
1443
Vacuum air blower motor M423 failure
The error signal from the M423 vacuum motor 3
is received by the control board.
1444
Vacuum air blower motor M424 failure
The error signal from the M424 vacuum motor
4is received by the control board.
If this error occurs frequently, call your local
dealer.
1451
Output shifting timeout error
Even though the M461 output shift conveyor
sliding motor moved for a specified time, the
B463 output shift conveyor front home position
sensor or the B464 output shift conveyor rear
home position sensor was not turned on.
Check if there is something to interrupt the
operation of the output shift conveyor.
1499
K403 Emergency Stop contactor function error
Though the interlock circuit is closed (=all the
Emergency Stop buttons are not pressed), the
contact points for terminals 21 and 22 on K403
are open.
Check the following in order:
- The Emergency stop button is not pressed.
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
1501
Deposition of K501 Interlock Contactor 1
Even though the contact points of S501/S502/
S503/S504/S505 are open, the contact points of
K501 are closed.
Check the following in order:
- All the covers are properly closed.
If this error occurs frequently, call your local
dealer.
1502
Deposition of K502 Interlock Contactor 2
Even though the S500 Emergency Stop button
is pressed or the contact points of S501/S502/
S503/S504/S505 are open, the contact points of
K501 are closed.
Check the following in order:
- All the covers are properly closed.
- The Emergency Stop button is not pressed.
If this error occurs frequently, call your local
dealer.
Summary of Contents for SmartStacker
Page 106: ...This page is intentionally left blank ...
Page 110: ...110 SmartStacker User s Manual Daily Safety Check Lift the cover pressing the hooks Hooks ...
Page 146: ...This page is intentionally left blank ...
Page 170: ...This page is intentionally left blank ...
Page 206: ...This page is intentionally left blank ...
Page 207: ...6 This chapter explains some possible problems and suggests some solutions 6 Troubleshooting ...
Page 367: ...367 SmartStacker User s Manual If a Jam Occurs B2 Stacker Option 10606650901C1 Feeder Option ...
Page 368: ...This page is intentionally left blank ...
Page 376: ...376 SmartStacker User s Manual SmartStacker Merge Conveyor Merge Stacker B2 Stacker Optional ...
Page 379: ...379 SmartStacker User s Manual SmartStacker B2 Stacker Optional Vacuum Belt ...
Page 381: ...381 SmartStacker User s Manual SmartStacker Merge Conveyor ...
Page 390: ...This page is intentionally left blank ...
Page 391: ...6 8 This chapter lists the specifications for this machine 8 Appendix ...
Page 411: ...This page is intentionally left blank ...
Page 412: ...Manufacturer Phone 81 75 934 6700 Fax 81 75 934 6708 www horizon co jp ...