Horizon Fitness QC-S30 Install Manual Download Page 8

2

Installing a Single QC-S300/QC-S30 Collator

* Choose a stable table which can support at least 73

kg (160.6 lb) to install QC-S300/QC-S30.

1.

Unpack the collator.

• This machine must be moved by at least two people.
• Check the accessories. 

2.

Install each QC-S300/QC-S30 on the table 
by following the steps below.

If optional MT-100 table is used, follow 

the steps (1) through (3) described below.

(1) Attach the base plate at the bottom of the QC-

S300/QC-S30 using two mounting screws.

• Attach the base plate in the correct direction referring

to the figure to the right. (Two left feet enter the holes
on the base plate.)

(2) Place the QC-S300/QC-S30 on the MT-100.

• Insert the projection on the base plate into the holes on

MT-100.

(3) Install four skirts. 

• Be sure to push the bottom of the transport door side

of the QC-S300/QC-S30 when moving the machine.
Do not push the bin side. This could cause the QC-
S300/QC-S30 to fall over.

How to Install a Single QC-S300/QC-S30 Collator

21101
10101E1

1,030 (40.5")

340 (13.3")

196 (7.7")

960 (37.8")

363 (14.3")

138 (5.4")

mm(inch)

Table Height : 600mm (23.7")

21101
20102N1

1,030 (40.6")

84 (3.4")

220 (8.7")

196 (7.8")

994 (39.2")

363 (14.3")

mm(inch)

Table Height : 572mm (22.6")

* If optional table MT-100 is used, installation space

is mentioned below.

 

CAUTION

• Do not install the QC-S300/QC-S30 on an 

unstable floor. The machine may fall over. 
The machine frame may be twisted, and this 
could affect the machine performance. 

• The QC-S300/QC-S30 weighs about 73Kg 

(160.6 lb). This machine must be installed 
by at least two people.

Important

Important

 

CAUTION

• Be sure to turn off the power switch on the 

QC-S300/QC-S30.

21101

20101L1

21101

20101J1

Mounting 

Screw

Projection

Left Feet

Base Plate

21101

20102M1

MT-100

Skirt

Summary of Contents for QC-S30

Page 1: ...Install Manual Provided By http www MyBinding com http www MyBindingBlog com Standard QC S300 S30 Collator...

Page 2: ...stallation Manual For UL QC S300 S30 510 Kuze Ooyabu cho Minami ku Kyoto 601 8206 Japan Phone 81 75 934 6700 Fax 81 75 934 6708 URL http www horizon co jp TABLE TOP COLLATOR UM201105 00 070406 QCS300Q...

Page 3: ...y the customer unauthorized modification or misuse or operation outside of the environmental specifications for the product Horizon International Inc pursues a policy of continuing improvement in desi...

Page 4: ...in explaining the details inside the machine Safety Precautions Safety precautions are indicated in this manual as follows The term WARNING indicates a potentially hazardous situation which if not avo...

Page 5: ...direct sunlight high tem perature or humidity Do not install the QC S300 QC S30 near any device which produces strong magnetic fields Do not install the QC S300 QC S30 in a location which is dusty Th...

Page 6: ...IV This page is intentionally left blank...

Page 7: ...mm inches 994 39 2 x 1 602 63 1 x 1 030 40 5 How to Install Multiple QC S300F QC S30F Collators 4 Multiple Collators QC S300 QC S30 QC S300F QC S30F QC S300F QC S30F Installation Space in mm inches 96...

Page 8: ...push the bottom of the transport door side of the QC S300 QC S30 when moving the machine Do not push the bin side This could cause the QC S300 QC S30 to fall over How to Install a Single QC S300 QC S3...

Page 9: ...hrough 3 3 Plug the power cord into the QC S300 QC S30 4 Plug the power cord into an outlet Plug the power cord into a properly grounded outlet If you must use an ungrounded outlet be sure to ground t...

Page 10: ...0101C1 Solenoid Connector 1 pc Support Guide l154294 1 pc Gear M092610 Clevis Pin 1 pc each 21101 20101D1 21101 20101E1 21101 20101F1 Conveyor Support Plate 1 pc Bridge 1 pc Connecting Plate 1 pc B4 8...

Page 11: ...left of the other QC S300F QC S30F unit as shown in the illustration viewed from the front Be sure to push the bottom of the transport door side of the QC S300F QC S30F when moving the machine Do not...

Page 12: ...F 1 Remove the locking screw on the middle con veyor How to Install Multiple QC S300F QC S30F Collators Preparation for Multiple QC S300F QC S30F Collators 21101 20101M1 Rear Cover 21101 20101N1 Gear...

Page 13: ...ne 2 Attach the gear using a clevis pin 3 Rotate the pulley by hand and check that the gear turns smoothly 4 Attach the gear cover using three screws Be careful that the nearby cables are not caught H...

Page 14: ...e two positioning pins on the conveyor support plate into the two holes on the bottom of the conveyor When inserting the positioning pin move the QC S300 QC S30 5 Attach the lower conveyor using the c...

Page 15: ...upport guide next to the connector using a screw 2 Attach the accessory cover on the rear of the QC S300 QC S30 using the screw removed in previ ous step 3 Attach solenoid connector A to the right con...

Page 16: ...pin inside the machine A pin on the bin shelf fits into a notch in the frame of the machine 2 On the near side of the machine fit the arm under the pin inside the machine A pin on the bin shelf fits i...

Page 17: ...ine due to by static electricity lightning strikes or current leakage How to Install Multiple QC S300F QC S30F Collators Important WARNING Do not attach the ground to a gas pipe 21101 20102K1 Power Co...

Page 18: ...12 This page is intentionally left blank...

Reviews: