35
5.5 Troubleshooting-No Response For Machine When Pressing Start
3. T7-02& T9-02 series windings test - Disconnect power from the unit. Remove the motor cover.
Remove the motor connection from the MCB. With an Ohm meter test the resistance level between the
motors three phases; pin 1 and pin 2, pin 1 and pin 3, then pin 2 and pin 3. If all three resistance
levels are the same, the motor is good. If one or more are different, replace the motor.
4. If the drive motor is normal Then
- Check the connection of the speed sensor (encoder disk group) at the MCB.
- Remove the speed sensor from the motor and clean it, then re-test.
- If the speed sensor is clean and has a good connection but still will not operate, replace the
Speed sensor.
- Replace the MCB as the last step if machine does still not run after to take above actions.
5.6 Troubleshooting-Incline Motor Issues
SOLUTION:
a. While using the machine press the "INCLINE" keys, the console should beep and display incline
change, if no, replace the key pad.
b. Enter Engineering Mode, and scroll to ENG 1 (Hardware Test).
c. Press the “INCLINE ↑
/ ↓”
key.
I
f can hear clicks
from two relays and LED light (see table 5.3.1 page 30 or 5.3.2 page31)
at the MCB
,
the MCB is ok. Then check the connection of the elevation motor at the MCB. First try to
unplug and re-plug connection . If this does not resolve the issue, replace the elevation motor.
If there is no clicks from these two relays or LED light, MCB is defective and replace the MCB.
CHAPTER 5: Troubleshooting
Summary of Contents for Elite T5
Page 2: ...2 Production Browse Elite T5 TM723 ...
Page 3: ...3 Production Browse Elite T7 02 TM475C ...
Page 4: ...4 Production Browse Elite T9 02 TM724 ...
Page 7: ...7 Serial Number Location T5 T7 02 T9 02 CHAPTER 1 Serial Number Location ...
Page 15: ...15 3 0 Engineering mode instruction CHAPTER 3 Engineering mode ...
Page 16: ...16 3 0 Engineering mode instruction CHAPTER 3 Engineering mode ...
Page 26: ...26 CHAPTER 5 Troubleshooting 5 1 Electric Diagram Elite T5 T7 02 T9 02 MCB ...
Page 27: ...27 CHAPTER 5 Troubleshooting 5 1 Electric Diagram Elite T5 T7 02 T9 02 UCB ...
Page 31: ...31 5 3 MCB Instructions 5 3 1 Elite T5 MCB Instructions CHAPTER 5 Troubleshooting ...
Page 32: ...32 5 3 MCB Instructions 5 3 1 Elite T5 MCB Instructions CHAPTER 5 Troubleshooting ...
Page 33: ...33 5 3 MCB Instructions 5 3 2 Elite T7 02 T9 02 MCB Instructions CHAPTER 5 Troubleshooting ...
Page 40: ...40 CHAPTER 5 Troubleshooting 1 2 Shows DHCP was unable to obtain an IP Address ...
Page 42: ...42 CHAPTER 5 Troubleshooting 1 4 Shows Unable to Connect to Via Fit at this time ...
Page 46: ...46 CHAPTER 5 Troubleshooting 3 2 Workouts from Via Fit equipment do not post to ...