Multi-Source Function System 7001RC - V02.01
17 / 31
hopf
Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
2.3.1.1 Status Table for Automatic Source Changeover
The following table shows the sync. source that is automatically selected for changeover,
together with its respective status.
Changeover takes place dependent on:
•
The primary and secondary sources selected
•
The reception status of the respective sync. source
•
The timer for loss of synchronisation of the system status
Primary
Source
Status
Secondary
Source
Status
System
status
"Sync. Status change
after sync. fail" Timer
System switches or
remains on
- -
C / -
--
Primary source
- -
R / r
running
Remains on
last sync.
source with system quartz
time
until
timer
expires
R -
- / C / r / R
--
Synchronised with
primary
source
R
R
- / C / r / R
--
always synchronised with
primary source
-
R
R / r
running
Remains on primary source
until
timer
expires
- R
- / C / r / R
--
Synchronised with
secondary source
Source Status
-
The source (channel) is not currently
connected or cannot be evaluated and is
not available for synchronisation.
R
Source is successfully evaluated and can
be used to synchronise the system.
System Status
-
System does not have a valid time
C
•
System has a valid time.
•
System runs with quartz time.
r
•
System synchronised at this
moment
or
•
System loses synchronisation at
this moment
R
•
System is synchronised and the
internal quartz base is controlled.
or
•
“Sync. Status change after sync.
fail” timer is active after
synchronisation.