H
OUSING
I
NSTALLATION
8 / 14
4465AC/4475AC/4800AC/6870AC/6875AC Additional Technical Manual - V01.03
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
2
Housing Installation
The DIN Rail Module can be clipped on to all DIN rails per DIN EN 50 022 and is designed
for horizontal mounting.
Installation dimensions
The dimensions of the housing can be found in
Chapter 4.4 Dimensions
•
4465AC with integrated AC power supply
Housing TYPE 2
•
4475AC with integrated AC power supply
Housing TYPE 2
•
4800AC with integrated AC power supply
Housing TYPE 2
•
6870AC with integrated AC power supply
Housing TYPE 2
•
6875AC with integrated AC power supply
Housing TYPE 2
In order to guarantee satisfactory convection we recommend the following
minimum distance from other modules:
•
5.0 cm in a vertical direction
•
1.0 cm in a horizontal direction
2.1
Mounting
Place the rail guide bar of the module against the lower edge of the DIN rail, push the
module upwards and clip into place at the top.
2.2
Demounting
Push the module upwards and then tip forward to remove from the DIN rail.