background image

i

There are two belts on your cleaner. The belts drive the agitator and the

power drive pulley and are important for the efficient operation of your

cleaner. Because of this, when buying new belts, you should always insist
on genuine HOOVER belts. Some other belts on the market, not manufac-
tured under the Hoover design and quality controls, may not operate the
agitator or ‘Power Drive’ correctly and may damage your cleaner,

When to replace belts 

Check from time to time to be sure the belts are

in good condition. If they are stretched or cut, they should be replaced.

TO REPLACE BELTS

Remove cord from electrical outlet.

Turn cleaner over   remove metal

plate on bottom of cleaner by push-
ing latches toward the outside of

cleaner. (Fig. 1). Lift plate to release

it from clips.

There are two belts as shown in Fig.
2. The larger belt is connected to the
agitator. To remove the large belt,
push latches that hold agitator in and
toward center of cleaner until they

are free. (Fig. 2). Lift out agitator and
remove old belt. (Fig. 3).

The smaller belt is attached to the
power drive pulley. (Fig. 2). To re-
place the smaller belt, it is necessary
to first remove the larger belt. Note:

It may not be necessary to change

both belts at one time.

Place new smaller belt over power

drive pulley and motor pulley with
smooth side of belt next to pulleys.

(Fig. 2). Next, place new larger belt

over motor pulley, then over agitator.

(Fig. 3).

Summary of Contents for Dial-A-Matic U6049

Page 1: ...I HOOVER Model Owner s Dial A Matic U6049 Manual Cleaner with Automatic Rd PowerDrive 1...

Page 2: ...l number and serial number in the spaces provided above and retain in a safe place The model number appears on the bottom of the cleaner and the serial number is on the bag door latch plate Save INDEX...

Page 3: ...fine materials such as powder 2 l Grasp the plug to disconnect from wall outlet to avoid damage to cord plug prongs or receptacle 1 l The use of an extension cord is not recommended i l If cleaner is...

Page 4: ...CARPET AND TOOL SUCTION ADJUSTMENT DIAL AND INTERLOCK OPENING FOR CLEANING ATTACHMENTS NOZZLE HOSE FULL BAG INDICATOR SOME MODELS HEADLIGHT SOME MODELS ONLY WRAP AROUND FURNITURE GUARD Warning Electr...

Page 5: ...perating the cleaner The Power Drive feature is in operation only when the motor is turned on To move the cleaner without operating the motor use the trans port button disengage drive according to the...

Page 6: ...on as shown in Fig 3 When the button is pressed in the automatic Power Drive gears are locked into neutral position and the cleaner can easily be transported FIG 3 _ _ Edge cleaning feature Provides i...

Page 7: ...n hose in opening below dial and turn the hose connector in a clockwise direction until it locks into place Set the suction regulator on the cleaner to MAXIMUM TOOL SUCTION 2 Adjust suction A second s...

Page 8: ...ve the detergent Cleaning tools can be washed in warm water with a detergent Rinse and let dry before using Maintenance Proper cafe of your cleaner will insure operation at peak performance Don t pick...

Page 9: ...d to filter out dust while allowing air to flow through freely Genuine HOOVER bags can be identified by the following trademarks CAUTION Very fine materials such as face powder cornstarch fireplace as...

Page 10: ...ove wire holder and lift out filter After new bag is installed close bag housing and set suction dial for cleaning tools Plug cleaner into electrical outlet turn on and tap filter against opening belo...

Page 11: ...om electrical outlet Turn cleaner over remove metal plate on bottom of cleaner by push ing latches toward the outside of cleaner Fig 1 Lift plate to release it from clips There are two belts as shown...

Page 12: ...s are pushed back and will not be covered by plate Fig 6 Place plate in position and latch securely Turn agitator by hand to be sure that belt is in proper position on pulley 1 Brushes When brushes ar...

Page 13: ...gently with a hammer to release other plate and end section Fig 7 Pull other plate and shaft from agita tor Fig 8 Remove brushes by pulling them from agitator Slide new brushes into chan nels small en...

Page 14: ...ght screws from the inside of the front bag cover See Fig 1 4 Place hand in carrying handle and pull out and up to remove front cover See Fig 2 5 Push bulb into socket and twist to remove Replace with...

Page 15: ...re handle grip slides pushed down freely If the problem persists check the telephone book for a HOOVER COMPANY listing or consult the white insert accompanying this manual for the nearest location whe...

Page 16: ...plugged in when unattended Turn machine off at switch before unplugging from wall outlet When unplugging machine grasp plug not cord Always unplug power cord from wall outlet before servicing machine...

Reviews: