If you have a hose without switches, the
Power Canister will start as soon as the
hose is inserted into the wall valve.

If you have a hose with a switch, then
the Power Canister can be turned ON or
OFF with the switch.

The Power Canister can also be turned
ON and OFF with the switch found on
the upper section of the motor module.

Check the System

Check each connection for proper seal
and that no air leaks occur. If one is pre-
sent, you may hear a “hissing” sound.

4

2. Installation

3. How to use

Location for power
canister

The Power Canister can be mounted in
the basement, utility room, garage or
any other remote area, except where
exposed to weather, and convenient to
an electrical outlet.  The unit requires
ventilation.  

DO NOT

install in a heat

producing or confined area such as the
attic, furnace room, etc.  If desired, the
Power Canister can be exhausted to the
outside.
The top of the Canister should be no
less than 12” (30.5 cm) from the ceiling,

and any corner wall,

to allow proper

cooling to the motor.  For ease of remov-
ing the dust container, the bottom of the
unit should be at least 18” (46 cm)
above the floor.
Central Vacuum Power Canisters require
a separate/dedicated, 120 Volt, 60Hz.,
20 Amp, 3 wire grounded power circuit,
protected by a 120 Volt, 60 Hz., AC, 20
Amp time delay fuse or circuit breaker
and a 120 Volt, 60 Hz., 20 Amp ground-
ed receptacle.
If a 120 volt, 60 Hz., 20 Amp grounded
receptacle is not available, have a quali-

fied electrician install one for you.  The
receptacle should be no more than 5
feet (152 cm) from the Power Canister.

UNDER NO CIRCUMSTANCES
SHOULD AN EXTENSION CORD BE
USED WITH THIS CANISTER.

Mounting the power
canister

1)

Determine if the wall you will be 
mounting the Canister to is block, 
concrete, or plaster/drywall.

2)

Block or Concrete Wall

You will need (2) 1-1/2” (3.8 cm) x 
1/4” (.64 cm) lead plugs and (2) 1-
1/2” (3.8 cm) x 1/4” (.64 cm) lag 
bolts.  Drill a 1/2” (1.3 cm) dia. x 1-
3/4” (4.4 cm) deep hole with a 
masonry drill bit.  Insert a lead plug 
into the hole.  

Mount the bracket (Fig. 2-1) from a 
top hole with a lag bolt.  Mark the 
other upper hole of the bracket.  
Make sure that the bracket is 
straight.  Slide the bracket away 
from the mark and drill a hole direct-
ly over the mark.  
Insert a lead plug into the hole.  
Align the bracket over the hole and 
tightly fasten with a lag bolt. 
Continue to 4).

3)

Drywall or Plaster Wall

You will need(2) 1-1/2” (3.8 cm) x 
1/4” (.64 cm) wood screws.  Locate 
a stud and drill a 1/8” (.32 cm) dia. 
x 1-3/4” (4.4 cm) pilot hole.  Mount 
the bracket from a top hole with a 
wood screw.  Make sure that the 
bracket is straight.  Drill a second 
pilot hole using a lower hole on the 
bracket and fasten tightly with the 
other wood screw.

4)

Mount the Power Canister on the 
bracket making sure the bar on the 
back of the machine is settled to the
bottom of the slots on the mounting 
bracket. The wall mounting bracket 
must fit between the two brackets 
on the back of the central vacuum.

10) Plug the power cord in.

11) Assuming that the wall inlet valves 

are connected, the system is now 
ready. 

3-1

3-2

A

A

A

B

2-1

2-2

5)

Route the intake tubing to the 
Canister.

6)

Insert the tubing into the Canister 
inlet.

7)

Tighten the inlet connection with the 
3” (7.6 cm) gear clamp (included). 

(Do not cement pipe to plastic 
inlet port.)

8)

When venting the exhaust air, a 
noise reducing exhaust muffler (A) is
included, which is installed inline in 
the piping to vent outside or it can 
be installed to vent indoors as 
shown in Fig. 2-2. Connect to the 
exhaust (right hand side near to of 
unit). Tighten the exhaust connec-
tion with the gear clamp (included). 

(Do not cement pipe to plastic 
exhaust port.)

9)

Connect the 24 Volt wires coming 
from the wall valves into the 24 Volt 
receptacle on the machine.

TOP

MOUNTING
BRACKET

Hose inlet port (S5626 &
S5636 models only) 

Insert the hose into the hose inlet (A) as
shown in Fig. 3-2. The power unit is
turned ON and OFF with the switch
found on the upper section of the motor
module.

To start your Power Canister, simply plug
your hose end into any wall inlet valve.
Both types of wall valves (Standard (A) -
Corded Hose; Electrified (B) - Cordless
Hose) are shown in Fig 3-1.

Summary of Contents for 120 V 60 HZ

Page 1: ...fore being shipped from the factory If you should happen to need assistance during assembly or operation Call 1 800 944 9200 for automated referral of authorized service outlet locations U S only OR V...

Page 2: ...en cleaning stairs Do not put any objects into openings Do not use with any openings blocked keep free of dust lint hair and anything that may reduce air flow Do not pull or carry by cord use cord as...

Page 3: ...ta cle E if a properly grounded outlet is not available The Temporary adapter should be used only until a properly grounded outlet C can be installed by a qualified electrician The green col ored rigi...

Page 4: ...nsert a lead plug into the hole Mount the bracket Fig 2 1 from a top hole with a lag bolt Mark the other upper hole of the bracket Make sure that the bracket is straight Slide the bracket away from th...

Page 5: ...is in the pipe insert hose into wall valve and place hand over end of hose to cut off air flow Place your hand on and off the end of hose rapid ly several times If this does not clear the blockage co...

Page 6: ...ost of parts only for the time periods given above For Canada see Canadian Warranty This warranty does not apply if the power unit is used in a commercial or rental applica tion This warranty covers a...

Page 7: ...replacement parts or accessories are used For commercial or rental use the war ranty is limited to three 3 months from date of purchase This warranty is not applicable to Hoover products sold in those...

Page 8: ...par le cordon d alimentation d utiliser le cordon pour trans porter ou soulever l appareil de coincer d craser ou de tirer le cordon autour de coins ou d ar tes vives S assurer que l appareil ne pass...

Page 9: ...l dans un sous sol une buanderie un garage ou tout autre emplacement qui le prot ge des intemp ries et distance raisonnable d une prise d alimentation lectrique Cet appareil exige une bonne ventilatio...

Page 10: ...mit du boyau et la remettre sur celle ci plusieurs fois et rapidement Si cela ne fonctionne pas contacter votre Centre de service en usine Hoover r gional V rifier les accessoires de nettoyage les ra...

Page 11: ...er En cas d utilisation commerciale ou de loca tion la garantie est de trois 3 mois partir de la date d achat La pr sente garantie ne s applique pas aux produits Hoover vendus dans les provinces dont...

Page 12: ...HOOVER et sont des marques d pos es HOOVER and are registered trademarks R2 4 05 S5615 25 26 35 36 Printed in Canada Imprim aux Canada 59132068...

Reviews: